About |
---|
ULTEM™ 9085 resin High flow Polyetherimide blend. Meets FAR 25.853 and OSU 55/55 with low toxicity, smoke and flame evolution.&&ULTEM™ 9085 resin High flow Polyetherimide blend. Meets FAR 25.853 and OSU 65/65 with low toxicity, smoke and flame evolution.&& |
Product Description | |
---|---|
Supplier | SABIC |
Generic | Polyetherimide |
Material Status | Commercial: Active |
Features | Low smoke,High liquidity,Low toxicity |
Availabilitys | North America,Asia Pacific,Europe |
Process Methods | Profile extrusion |
Technical Data | |||
---|---|---|---|
PHYSICAL | Nominal value | Unit | Test method |
Density | 1.34 | g/cm³ | ASTM D792 |
Density | 1.34 | g/cm³ | ISO 1183 |
Melt Flow Rate | |||
295℃,6.60kg | 8.9 | g/10min | ASTM D1238 |
Melt Volume Rate | |||
360℃,5 kg | 65.5 | cm³/10min | ISO 1133 |
Shrinkage rate | |||
MD:3.2 mm | 0.50 to 0.70 | % | Internal Method |
Water absorption rate | |||
Saturation, 23 ℃ | 0.39 | % | ISO 62 |
Equilibrium, 23 ℃, 50% RH | 0.17 | % | ISO 62 |
MECHANICAL | Nominal value | Unit | Test method |
---|---|---|---|
Tensile modulus | 3440 | MPa | ASTM D638 |
Tensile modulus | 3050 | MPa | ISO 527-1-2 |
tensile strength | |||
fracture | 71.0 | MPa | ISO 527-2/5 |
fracture | 74.0 | MPa | ASTM D638 |
yield | 88.0 | MPa | ISO 527-2/5 |
yield | 84.0 | MPa | ASTM D638 |
Tensile strain | |||
fracture | 72 | % | ASTM D638 |
fracture | 50 | % | ISO 527-2/5 |
yield | 6.7 | % | ISO 527-2/5 |
yield | 7.0 | % | ASTM D638 |
Bending modulus | 2750 | MPa | ISO 178 |
50 mm span | 2920 | MPa | ASTM D790 |
bending strength | 90.0 | MPa | ISO 178 |
bending strength | |||
Yield, 50 mm span | 138 | MPa | ASTM D790 |
IMPACT | Nominal value | Unit | Test method |
---|---|---|---|
Impact strength of cantilever beam notch | |||
23℃ | 120 | J/m | ASTM D256 |
23℃ | 13 | kJ/m² | ISO 180-1A |
THERMAL | Nominal value | Unit | Test method |
---|---|---|---|
Hot deformation temperature | |||
1.8 MPa, unannealed, 64 mm span | 152 | ℃ | ISO 75-2/Af |
1.8 MPa, unannealed, 3.2 mm | 153 | ℃ | ASTM D648 |
Vicat Softening Temp | |||
B120 | 173 | ℃ | ISO 306/B120 |
FLAME CHARACTERISTICS | Nominal value | Unit | Test method |
---|---|---|---|
Extreme oxygen index | 49 | % | ASTM D2863 |
FAA Flammability | <5 | FAR 25.853 | |
OSU peak heat release rate | 36.0 | kW/m² | FAR 25.853 |
OSU total heat release | 16.0 | kW·min/m² | FAR 25.853 |
Vertical combustion test | |||
Test a,60 s,passes at | 2.0 | sec | FAR 25.853 |
Process Conditions | |||
---|---|---|---|
injection | Nominal value | Unit | Test method |
Extrusion | Nominal value | Unit | Test method |
Drying temperature | 135 | °C | |
Drying time | 4.0 to 6.0 | hr | |
Recommended maximum moisture content | 0.020 | % | |
Recommended injection volume | 40 to 60 | % | |
Barrel rear temperature | 315 to 340 | °C | |
Barrel middle temperature | 325 to 345 | °C | |
Barrel front temperature | 330 to 350 | °C | |
Nozzle temperature | 330 to 350 | °C | |
Processing (melt) temperature | 330 to 350 | °C | |
Mold temperature | 120 to 150 | °C | |
Back pressure | 0.300 to 0.700 | MPa | |
Screw speed | 40 to 70 | rpm | |
Vent depth | 0.025 to 0.076 | mm | |
Drying temperature | 120 to 130 | °C | |
Drying time | 4.0 to 6.0 | hr | |
Recommended maximum moisture content | 0.020 | % | |
Hopper temperature | 80 to 100 | °C | |
Barrel 1 zone temperature | 265 to 275 | °C | |
Barrel 2 zone temperature | 280 to 295 | °C | |
Barrel 3 zone temperature | 290 to 305 | °C | |
Barrel 4 zone temperature | 295 to 310 | °C | |
Connector temperature | 270 to 310 | °C | |
Melt temperature | 280 to 310 | °C | |
Nozzle temperature | 260 to 310 | °C | |
Calibration temperature, first time | 130 to 160 | °C | |
Calibration Temp, Second | 80 to 120 | °C |
Notes |
---|
【 Disclaimer 】 Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials. |