VALOX™ ENH4530 resin

About
15% GF PBT, Non-Brominated & Non-Chlorinated Flame retardant&&

Product Description
SupplierSABIC
Genericpolybutylene terephthalate
Material StatusCommercial: Active
FeaturesHalogen free,Flame Characteristics,V-0
AvailabilitysEurope
Process MethodsInjection Molding

Technical Data
IMPACTNominal valueUnitTest method
Charpy Notched Impact StrengthISO 179/2C
-30℃6.0kJ/m²
23℃6.0kJ/m²
Charpy Unnotch Impact strengthISO 179/2U
-30℃25kJ/m²
23℃35kJ/m²
Impact strength of cantilever beam notch
-30℃50J/mASTM D256
0℃50J/mASTM D256
23℃50J/mASTM D256
-30℃6.0kJ/m²ISO 180-1A
0℃6.0kJ/m²ISO 180-1A
23℃6.0kJ/m²ISO 180-1A
Notched impact strength of cantilever beam
-30℃360J/mASTM D4812
23℃400J/mASTM D4812
-30℃23kJ/m²ISO 180/1U
23℃30kJ/m²ISO 180/1U

THERMALNominal valueUnitTest method
Hot deformation temperature
0.45 MPa, unannealed, 3.2 mm220ASTM D648
0.45 MPa, unannealed, 64 mm span220ISO 75-2/Bf
1.8 MPa, unannealed, 3.2 mm200ASTM D648
1.8 MPa, unannealed, 64 mm span200ISO 75-2/Af
Vicat Softening Temp
B50205ASTM D1525, ISO 306/B50, ISO 306/B120 20
217ASTM D1525 21
A50220ISO 306/A50
Ball pressure test
125℃PassIEC 60695-10-2
Linear coefficient of thermal expansionISO 11359-2
MD:-40~40℃2.9E-51/℃
MD:23~150℃4.2E-51/℃
TD:-40~40℃7.0E-51/℃
TD:23~150℃1.7E-41/℃
Relative temperature index140UL 746
Electrical performance140UL 746
Impact mechanical performance120UL 746

Electrical performanceNominal valueUnitTest method
Surface resistivity> 1.0E+15ohmsIEC 60093
Volume resistivity1.0E+15ohms·cmASTM D257,IEC 60093
Dielectric strength
0.8 mm in oil28kV/mmASTM D149
1.6 mm in oil21kV/mmASTM D149
3.2 mm in oil17kV/mmASTM D149
0.8 mm in oil28kV/mmIEC 60243-1
1.6 mm in oil21kV/mmIEC 60243-1
3.2 mm in oil17kV/mmIEC 60243-1
Dielectric constant
1 MHz3.70ASTM D150,IEC 60250
Dissipation factor
1 MHz0.15ASTM D150,IEC 60250

FLAME CHARACTERISTICSNominal valueUnitTest method
0.80 mmV-0UL 94
Glowing wire flammability index
3.0 mm960IEC 60695-2-12
Igniting temperature of the hot wire
3 mm750IEC 60695-2-13

Supplementary informationNominal valueUnitTest method
Filler15%ASTM D229

MECHANICALNominal valueUnitTest method
Rockwell hardness
R-level98ISO 2039-2
Ball hardness
H358/30128MPaISO 2039-1
Tensile modulus
7300MPaASTM D638
7500MPaISO 527-1-2
tensile strength
yield80.0MPaASTM D638
yield80.0MPaISO 527-2/5
fracture80.0MPaASTM D638
fracture80.0MPaISO 527-2/5
Tensile strain
yield2.0%ASTM D638
yield2.0%ISO 527-2/5
fracture3.0%ASTM D638
fracture3.0%ISO 527-2/5
Bending modulus
50 mm span5800MPaASTM D790
6400MPaISO 178
bending strength
130MPaISO 178
Yield, 50 mm span120MPaASTM D790
Fracture, 50 mm span120MPaASTM D790
Fracture bending strain3.0%ISO 178

PHYSICALNominal valueUnitTest method
Density1.45g/cm³ASTM D792, ISO 1183
Melt Flow Rate
265℃,5.0kg24g/10minASTM D1238
Melt Volume RateISO 1133
250℃,5 kg17.0cm³/10min
265℃,5 kg18.0cm³/10min
Shrinkage rate
MD0.30 to 0.80%Internal Method
Water absorption rateISO 62
Saturation, 23 ℃0.15%
Equilibrium, 23 ℃, 50% RH0.070%
Apparent viscosity of melt
260℃,1500 sec^-1150Pa·sISO 11443

Process Conditions
injectionNominal valueUnitTest method
Drying temperature110 to 120°C
Drying time2.0 to 4.0hr
Recommended maximum moisture content0.020%
Hopper temperature40.0 to 60.0°C
Barrel rear temperature230 to 240°C
Barrel middle temperature235 to 250°C
Barrel front temperature240 to 260°C
Nozzle temperature230 to 255°C
Processing (melt) temperature245 to 260°C
Mold temperature40.0 to 100°C

Notes
1. Typical properties: these are not to be construed as specifications.
2. Tensile Bar
3. 0.20 in/min
4. Type I, 0.20 in/min
5. 0.051 in/min
6. 0.079 in/min
7. at Break
8. 2 mm/min
9. 80*10*4 mm
10. Rate A (50°C/h), Loading 1 (10 N)
11. Rate A (50°C/h), Loading 2 (50 N)
【 Disclaimer 】
Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials.