About |
---|
PETLIN LD M050X is a low density polyethylene resin designed primarily for injection molding applications. It is produced by the state-of-the-art DSM Stamicarbon tubular process. It contains antioxidant (BHT free).&& |
Product Description | |
---|---|
Generic | LDPE |
Material Status | Commercial: Active |
Features | Good surface appearance,High liquidity,Low speed solidification point,Food contact compliance,Inoxidizability |
Availabilitys | Asia Pacific |
Process Methods | Injection Molding |
Technical Data | |||
---|---|---|---|
PHYSICAL | Nominal value | Unit | Test method |
Density | 0.919 | g/cm³ | ISO 1183/A |
Melt Flow Rate | |||
190℃,2.16kg | 50 | g/10min | ISO 1133 |
ESCR(Environmental Stress Cracking Resistance) | 0.500 | hr | Internal Method |
IMPACT | Nominal value | Unit | Test method |
---|---|---|---|
Impact strength of cantilever beam notch | ISO 180/1A | ||
-30℃ | 5.0 | kJ/m² | ISO 180-1A |
23℃ | 41 | kJ/m² | ISO 180-1A |
THERMAL | Nominal value | Unit | Test method |
---|---|---|---|
Vicat Softening Temp | 78.0 | ℃ | ISO 306 |
Melting temperature | |||
DSC | 104 | ℃ | DIN 53765 |
MECHANICAL | Nominal value | Unit | Test method |
---|---|---|---|
Shore hardness | |||
Shaw’s D | 43 | ISO 868 | |
Tensile modulus | 168 | MPa | ISO 527-2 |
tensile strength | ISO 527-2 | ||
yield | 8.00 | MPa | ISO 527-2 |
fracture | 7.00 | MPa | ISO 527-2 |
Tensile strain | |||
fracture | 200 | % | ISO 527-2 |
Tensile creep modulus | ISO 899-1 | ||
1 hr | 73.0 | MPa | ISO 899-1 |
1000 hr | 38.0 | MPa | ISO 899-1 |
Process Conditions | |||
---|---|---|---|
injection | Nominal value | Unit | Test method |
Processing (melt) temperature | 180 to 210 | °C |
Notes |
---|
1. Typical properties: these are not to be construed as specifications. |
【 Disclaimer 】 Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials. |