| About |
|---|
| Product Description | |
|---|---|
| Supplier | SABIC |
| Generic | ABS |
| Material Status | Commercial: Active |
| Features | High impact resistance,Good liquidity,Electroplating |
| Availabilitys | North America,Latin America |
| Technical Data | |||
|---|---|---|---|
| PHYSICAL | Nominal value | Unit | Test method |
| Density | 1.05 | g/cm³ | ASTM D792 |
| Shrinkage rate | |||
| MD | |||
| MD | 0.5~0.7 | % | |
| Water absorption rate | |||
| Saturation, 23 ℃ | 1 | % | ISO 62 |
| 23℃,50% RH | 0.2 | % | ISO 62 |
| Melt Flow Rate | |||
| 220℃,10.0kg | 31 | g/10min | ISO 1133 |
| Melt Volume Rate | |||
| 220℃,10 kg | 33 | cm³/10min | ISO 1133 |
| MECHANICAL | Nominal value | Unit | Test method |
|---|---|---|---|
| Taber wear and tear | 109 | mg/1000cy | |
| tensile strength | |||
| Yield, 5 mm/min | 40 | MPa | ISO 527 |
| Fracture, 5 mm/min | 35 | MPa | ISO 527 |
| Yield, 50 mm/min | 45 | ISO 527 | |
| Fracture, 50 mm/min | 35 | ISO 527 | |
| Tensile strain | |||
| Yield, 5 mm/min | 2 | % | ISO 527 |
| Fracture, 5 mm/min | 20 | % | ISO 527 |
| Yield, 50 mm/min | 2 | % | ISO 527 |
| Fracture, 50 mm/min | 30 | % | ISO 527 |
| Tensile modulus | 2500 | MPa | ISO 527 |
| bending strength | |||
| yield | 69 | MPa | ISO 178 |
| Bending modulus | 2400 | MPa | ISO 178 |
| Rockwell hardness | |||
| R-level | 112 | ISO 2039-2 |
| THERMAL | Nominal value | Unit | Test method |
|---|---|---|---|
| Thermal conductivity coefficient | 0.2 | W/m/℃ | ISO 8302 |
| Ball pressure test | |||
| 75℃±2℃ | PASSES | IEC 60695-10-2 | |
| Vicat Softening Temp | |||
| B50 | 97 | ℃ | ISO 306 |
| B120 | 100 | ℃ | ISO 306 |
| Hot deformation temperature | |||
| 0.45 MPa, 100 mm span | 90 | ℃ | ISO 75/Be |
| 1.8 MPa, 100 mm span | 78 | ℃ | ISO 75/Ae |
| Linear expansion coefficient (-40 ° C~40 ° C) | |||
| MD | 8×10^-5 | 1/℃ | ISO 11359-2 |
| TD | 8×10^-5 | 1/℃ | ISO 11359-2 |
| Relative temperature index | |||
| Electrical performance | 60 | ℃ | UL 746B |
| Impact mechanical performance | 60 | ℃ | UL 746B |
| Non mechanical impact performance | 60 | ℃ | UL 746B |
| IMPACT | Nominal value | Unit | Test method |
|---|---|---|---|
| Impact strength of cantilever beam notch | |||
| 23℃ | 16 | kJ/m² | ISO 180-1A |
| -30℃ | 6 | kJ/m² | ISO 180-1A |
| Charpy impact strength | |||
| 23℃ | 16 | kJ/m² | ISO 180/1eA |
| -30℃ | 6 | kJ/m² | ISO 180/1eA |
| Electrical performance | Nominal value | Unit | Test method |
|---|---|---|---|
| Volume resistivity | >1×10^15 | ohms·cm | IEC 60093 |
| Surface resistivity | 1E+15 | ohms | IEC 60093 |
| Dielectric strength | |||
| 0.8 mm in oil | 35 | kV/mm | IEC 60243-1 |
| 1.6 mm in oil | 26 | kV/mm | IEC 60243-1 |
| 3.2 mm in oil | 18 | kV/mm | IEC 60243-1 |
| Relative permittivity | |||
| 1 MHz | 2.6 | IEC 60250 | |
| 50-60 Hz | 2.7 | IEC 60250 | |
| Dissipation factor | |||
| 50-60 Hz | 0.004 | IEC 60250 | |
| 1 MHz | 0.008 | IEC 60250 | |
| Compared to the leakage tracing index | 600 | V | IEC 60112 |
| FLAME CHARACTERISTICS | Nominal value | Unit | Test method |
|---|---|---|---|
| Flame retardant level | |||
| 1.50 mm | HB | UL 94 | |
| 2.50 mm | HB | UL 94 | |
| Burning wire flammability index 650 ° C passed | 1 | mm | IEC 60695-2-12 |
| Process Conditions | |||
|---|---|---|---|
| injection molding | Nominal value | Unit | Test method |
| Dry conditions | Nominal value | Unit | Test method |
| Melt Temperature | 250~270 | ℃ | |
| Nozzle temperature | 240~260 | ℃ | |
| Front temperature | 245~265 | ℃ | |
| Mid section temperature | 240~260 | ℃ | |
| Post stage temperature | 230~250 | ℃ | |
| Hopper temperature | 60~80 | ||
| Mold temperature | 65~80 | ℃ | |
| drying temperature | 85~95 | ℃ | |
| Drying time | 2~4 | hrs | |
| Maximum moisture content | 0.02 | % | |
| Notes |
|---|
| 【 Disclaimer 】 Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials. |