Durethan® BKV 30 H2.0 EF 901510

About
Durethan®   BKV30H2.0EF 901510 (Dry) PA 6, 30 % glass fibers, injection molding, improved flowability, heat-aging stabilized&&Durethan®   BKV30H2.0EF 901510 PA 6, 30 % glass fibers, injection molding, improved flowability, heat-aging stabilized&&Durethan®   BKV30H2.0EF 901510 PA 6, 30 % glass fibers, injection molding, improved flowability, heat-aging stabilized&&

Product Description
SupplierLANXESS
GenericPA6
Material StatusCommercial: Active
FeaturesGood heat aging resistance,Good liquidity,Heat Stabilized
AvailabilitysAfrica & Middle East ,North America,Latin America,Asia Pacific,Europe
Process MethodsInjection Molding

Technical Data
PHYSICALNominal valueUnitTest method
Density1.35g/cm³ISO 1183
Apparent density0.60g/cm³ISO 60
Shrinkage rate ISO 294-4
TD:280℃,2.0 mm0.81%ISO 294-4
TD:120℃,2.0 mm,2 hrs0.10%ISO 294-4
MD:280℃,2.0 mm0.29%ISO 294-4
MD:120℃,2.0 mm,2 hrs0.050%ISO 294-4
Water absorption rate
Saturation, 23 ℃7.0%ISO 62
Equilibrium, 23 ℃, 50% RH2.1%ISO 62

filmNominal valueUnitTest method
Membrane puncture strength ISO 6603-2
2.10JISO 6603-2
2.20JISO 6603-2
Membrane puncture force ISO 6603-2
744NISO 6603-2
803NISO 6603-2

IMPACTNominal valueUnitTest method
Charpy Notched Impact Strength ISO 179/1eA
-30℃< 10kJ/m²ISO 179/1eA
23℃11kJ/m²ISO 179/1eA
Charpy Unnotch Impact strength ISO 179/1eU
-30℃55kJ/m²ISO 179/1eU
23℃65kJ/m²ISO 179/1eU
Impact strength of cantilever beam notch ISO 180/1A
-30℃< 10kJ/m²ISO 180-1A
23℃10kJ/m²ISO 180-1A
Notched impact strength of cantilever beam ISO 180/1U
-30℃55kJ/m²ISO 180/1U
23℃60kJ/m²ISO 180/1U

THERMALNominal valueUnitTest method
Hot deformation temperature
8.0 MPa, unannealed150ISO 75-2/C
1.8 MPa, unannealed210ISO 75-2/A
0.45 MPa, unannealed219ISO 75-2/B
Vicat Softening Temp
B120210ISO 306/B120
Ball pressure test
210℃Pass IEC 60695-10-2
Melting temperature221ISO 11357-3
Linear coefficient of thermal expansion
TD:23~55℃1.0E-41/℃ISO 11359-2
MD:23~55℃2.0E-51/℃ISO 11359-2

Electrical performanceNominal valueUnitTest method
Dielectric strength
23 ℃,1 mm33kV/mmIEC 60243-1
Compared to the leakage tracing index
Solution A400VIEC 60112

FLAME CHARACTERISTICSNominal valueUnitTest method
Flame retardant levelpassed ISO 3795

Supplementary informationNominal valueUnitTest method
ISO ShortnamePA 6, GHR, 10-090, GF30 ISO 1874

MECHANICALNominal valueUnitTest method
Tensile modulus
23℃9400MPaISO 527-1-2
23℃8730MPaASTM D638
tensile strength
Fracture, 23 ℃165MPaASTM D638
Fracture, 23 ℃170MPaISO 527-2/5
Tensile strain
Fracture, 23 ℃3.0%ISO 527-2/5
Fracture, 23 ℃3.2%ASTM D638
Bending modulus
23℃8400MPaISO 178-A
23℃8000MPaASTM D790
bending strength 
23℃260MPaASTM D790
3.50% strain255MPaISO 178-A
23℃260MPaISO 178
Bending strain3.6%
Ball hardness193MPaISO 2039-1

Process Conditions
injectionNominal valueUnitTest method
Drying Temperature – Dry Air Dryer80°C
Drying Time – Dry Air Dryer2.0 to 6.0hr
Processing (melt) temperature250 to 290°C
Mold temperature80 to 120°C
Residual Moisture Content0.030 to 0.12%

Notes
1. Typical properties: these are not to be construed as specifications.
2. 60x60x2mm, 4 hr
3. 60x60x2mm, 120°C MT, 600 bar
4. 0.079 in/min
5. 2 mm/min
6. 10°C/min
【 Disclaimer 】
Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials.