About |
---|
Lexan* FST3403T resin is a high flow PC Copolymer Resin, suitable for injection molding. This halogen-free flame retardant resin is EN45545 R6 HL3 and an ideal candidate for train interior applications. It also meets requirements of NFPA-130 standards. Available in transparent and opaque colors.&& |
Product Description | |
---|---|
Supplier | SABIC |
Generic | Polycarbonate |
Material Status | Commercial: Active |
Features | High liquidity,Halogen free,Flame Characteristics,Copolymer |
Availabilitys | Europe |
Process Methods | Injection Molding |
Technical Data | |||
---|---|---|---|
PHYSICAL | Nominal value | Unit | Test method |
Density | 1.33 | g/cm³ | ASTM D792 , ISO 1183 |
Melt Flow Rate | |||
300℃,1.20kg | 9.0 | g/10min | ASTM D1238 |
Melt Volume Rate | |||
300℃,1.2 kg | 10.0 | cm³/10min | ISO 1133 |
Shrinkage rate | Internal Method | ||
MD | 0.50 to 0.70 | % | Internal Method |
TD | 0.50 to 0.70 | % | Internal Method |
MECHANICAL | Nominal value | Unit | Test method |
---|---|---|---|
Tensile modulus | |||
— | 2600 | MPa | ASTM D638 |
— | 2600 | MPa | ISO 527-1-2 |
tensile strength | |||
yield | 77.0 | MPa | ASTM D638 |
yield | 77.0 | MPa | ISO 527-2/50 |
fracture | 70.0 | MPa | ASTM D638 |
fracture | 70.0 | MPa | ISO 527-2/50 |
Tensile strain | |||
yield | 6.0 | % | ASTM D638 |
yield | 6.0 | % | ISO 527-2/50 |
fracture | 75 | % | ASTM D638 |
fracture | 95 | % | ISO 527-2/50 |
Bending modulus | |||
50 mm span | 2700 | MPa | ASTM D790 |
— | 2500 | MPa | ISO 178 |
bending strength | |||
— | 105 | MPa | ISO 178 |
Yield, 50 mm span | 115 | MPa | ASTM D790 |
IMPACT | Nominal value | Unit | Test method |
---|---|---|---|
Charpy Notched Impact Strength | ISO 179/1eA | ||
-30℃ | 无断裂 | ISO 179/1eA | |
23℃ | 无断裂 | ISO 179/1eA | |
Charpy Unnotch Impact strength | ISO 179/1eU | ||
-30℃ | 无断裂 | ISO 179/1eU | |
23℃ | 无断裂 | ISO 179/1eU | |
Impact strength of cantilever beam notch | |||
-30℃ | 85 | J/m | ASTM D256 |
23℃ | 120 | J/m | ASTM D256 |
-30℃ | 9.0 | kJ/m² | ISO 180-1A |
23℃ | 11 | kJ/m² | ISO 180-1A |
23℃ | 12 | kJ/m² | ISO 180-1A |
Notched impact strength of cantilever beam | ISO 180/1U | ||
-30℃ | 无断裂 | ISO 180/1U | |
23℃ | 无断裂 | ISO 180/1U | |
Dart impact equipped with measuring instruments | |||
23℃,Total Energy | 60.0 | J | ASTM D3763 |
— | 130 | J | ISO 6603-2 |
THERMAL | Nominal value | Unit | Test method |
---|---|---|---|
Hot deformation temperature | ASTM D648 | ||
0.45 MPa, unannealed, 3.2 mm | 104 | ℃ | ASTM D648 |
1.8 MPa, unannealed, 3.2 mm | 93.0 | ℃ | ASTM D648 |
Vicat Softening Temp | |||
— | 111 | ℃ | ASTM D1525 10 |
B120 | 113 | ℃ | ISO 306/B120 |
Linear coefficient of thermal expansion | ISO 11359-2 | ||
MD:-40~40℃ | 6.0E-5 | 1/℃ | ISO 11359-2 |
TD:-40~40℃ | 6.0E-5 | 1/℃ | ISO 11359-2 |
FLAME CHARACTERISTICS | Nominal value | Unit | Test method |
---|---|---|---|
Fire Safety Hazard Level(Requirement set R6) | HL3 | EN 45545-2 | |
Heat dissipation, MAHRE -50 kW/m ² | |||
3.00 mm | < 60.0 | kW/m² | ISO 5660-1 |
Smoke Toxicity – CITG(8 min),50 kW/m²(3.00 mm) | 0.100 | ISO 5659-2 | |
Smoke density | ISO 5659-2 | ||
DS-4,50 kW/m²:3.00 mm | < 150 | ISO 5659-2 | |
VOF4,50 kW/m²:3.00 mm | < 300 | ISO 5659-2 |
Process Conditions | |||
---|---|---|---|
injection | Nominal value | Unit | Test method |
Drying temperature | 95 to 100 | °C | |
Drying time | 6.0 to 8.0 | hr |
Notes |
---|
1. Typical properties: these are not to be construed as specifications. |
2. 0.20 in/min |
3. Type I, 2.0 in/min |
4. 0.051 in/min |
5. 0.079 in/min |
6. at Yield |
7. 80*10*4 sp=62mm |
8. 80*10*3 sp=62mm |
9. 80*10*4 mm |
10. 80*10*3 mm |
11. Rate A (50°C/h), Loading 2 (50 N) |
12. 50 kW/m² |
13. 1.5 min |
14. 4 min |
【 Disclaimer 】 Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials. |