Makrolon® 1837

About
MVR (300°C/1.2 kg) 11 cm³/10 min; impact modified; medium viscosity; easy release; injection molding – melt temperature 280 – 320°C; available in opaque colors only&&

Product Description
SupplierCovestro
GenericPolycarbonate
Material StatusCommercial: Active
FeaturesHigh impact resistance,Good stripping performance,HB
AvailabilitysAfrica & Middle East ,North America,Latin America,Asia Pacific,Europe
Process MethodsInjection Molding

Technical Data
PHYSICALNominal valueUnitTest method
Density1.19g/cm³ISO 1183
Apparent density0.64g/cm³ISO 60
Melt Flow Rate
300℃,1.20kg12g/10minISO 1133
Melt Volume Rate
300℃,1.2 kg11.0cm³/10minISO 1133
Shrinkage rate 
TD0.60 to 0.80%ISO 2577
MD0.60 to 0.80%ISO 2577
TD:2.0 mm0.70%ISO 294-4
MD:2.0 mm0.65%ISO 294-4
Water absorption rate ISO 62
Saturation, 23 ℃0.40%ISO 62
Equilibrium, 23 ℃, 50% RH0.12%ISO 62

IMPACTNominal valueUnitTest method
Charpy Notched Impact Strength ISO 7391
-30 ℃, localized fracture50kJ/m²ISO 7391
23 ℃, localized fracture60kJ/m²ISO 7391
Charpy Unnotch Impact strength ISO 179/1eU
-60℃无断裂 ISO 179/1eU
-30℃无断裂 ISO 179/1eU
23℃无断裂 ISO 179/1eU
Impact strength of cantilever beam notch ISO 7391
-30 ℃, localized fracture45kJ/m²ISO 7391
Multi axial instrumented impact energy ISO 6603-2
-30℃55.0JISO 6603-2
23℃50.0JISO 6603-2
Multi axial instrumented peak impact force ISO 6603-2
-30℃5800NISO 6603-2
23℃4900NISO 6603-2

THERMALNominal valueUnitTest method
Hot deformation temperature 
0.45 MPa, unannealed134ISO 75-2/B
1.8 MPa, unannealed121ISO 75-2/A
Glass transition temperature143ISO 11357-2
Vicat Softening Temp 
B50141ISO 306
B120143ISO 306/B120
Ball pressure test
134℃通过 IEC 60695-10-2
Linear coefficient of thermal expansion ISO 11359-2
MD:23~55℃7.0E-51/℃ISO 11359-2
TD:23~55℃7.0E-51/℃ISO 11359-2
Thermal conductivity coefficient
23℃0.20W/m/KISO 8302

Electrical performanceNominal valueUnitTest method
Surface resistivity1.0E+16ohmsIEC 60093
Volume resistivity
23℃1.0E+16ohms·cmIEC 60093
Dielectric strength
23 ℃,1 mm34kV/mmIEC 60243-1
Relative permittivity IEC 60250
23℃,100 Hz3.20 IEC 60250
23℃,1 MHz3.10 IEC 60250
Dissipation factor IEC 60250
23℃,100 Hz1.4E-3 IEC 60250
23℃,1 MHz0.013 IEC 60250
Compared to the leakage tracing index IEC 60112
Solution A225VIEC 60112
Solution B100VIEC 60112

FLAME CHARACTERISTICSNominal valueUnitTest method
Flame retardant level
0.75 mmHB UL 94
Glowing wire flammability index IEC 60695-2-12
0.75 mm850IEC 60695-2-12
1.5 mm875IEC 60695-2-12
3.0 mm900IEC 60695-2-12
Igniting temperature of the hot wire IEC 60695-2-13
1.5 mm825IEC 60695-2-13
2 mm825IEC 60695-2-13
3 mm850IEC 60695-2-13
Extreme oxygen index30%ISO 4589-2
Flash ignition temperature450ASTM D1929
Needle flame test IEC 60695-11-5
Method F:1.50 mm2.0minIEC 60695-11-5
Method F:2.00 mm2.0minIEC 60695-11-5
Method F:3.00 mm2.0minIEC 60695-11-5
Method K:1.50 mm0.1minIEC 60695-11-5
Method K:2.00 mm0.1minIEC 60695-11-5
Method K:3.00 mm0.2minIEC 60695-11-5
Autoignition temperature530ASTM D1929
Burning rate
USFMVSS,> 1.00 mmpassed ISO 3795

Supplementary informationNominal valueUnitTest method
ISO ShortnameISO 7391-PC,MP,(,,)-09-9 

MECHANICALNominal valueUnitTest method
Ball hardness104MPaISO 2039-1
Tensile modulus
23℃2200MPaISO 527-1-2
tensile strength ISO 527-2/50
Yield, 23 ℃58.0MPaISO 527-2/50
Fracture, 23 ℃60.0MPaISO 527-2/50
Tensile strain ISO 527-2/50
Yield, 23 ℃5.7%ISO 527-2/50
Fracture, 23 ℃120%ISO 527-2/50
Nominal tensile fracture strain
23℃> 50%ISO 527-2/50
Bending modulus
23℃2200MPaISO 178
bending strength ISO 178
23℃86.0MPaISO 178
3.50% strain, 23 ℃68.0MPaISO 178
Bending strain
23℃6.8%ISO 178

Notes
1. Typical properties: these are not to be construed as specifications.
2. Pellets
3. 60x60x2mm, 500 bar
4. 0.079 in/min
5. 2 mm/min
6. Type 1, Edgewise, Notch A
7. 3mm
8. Notch A
9. 10°C/min
10. Across Flow
11. Procedure A
12. US-FMVSS
13. Method K
14. Method F
【 Disclaimer 】
Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials.