Makroblend® EL700

About
(PC+PET) blend; unreinforced; flame-retardant; impact modified; injection molding grade. Good impact strength, dimensional stability and chemical resistance. Uses include indoor electrical enclosures.&&

Product Description
SupplierCovestro
GenericPC+PET
Material StatusCommercial: Active
FeaturesHigh impact resistance,Good Dimensional Stability,Flame Characteristics,Solvent resistance,V-0
AvailabilitysAfrica & Middle East ,North America,Latin America,Asia Pacific,Europe
Process MethodsInjection Molding

Technical Data
PHYSICALNominal valueUnitTest method
Density1.28g/cm³ISO 1183
Melt Volume Rate
270℃,5 kg15.0cm³/10minISO 1133
Shrinkage rate ISO 2577
TD0.60 to 0.80%ISO 2577
MD0.60 to 0.80%ISO 2577
Water absorption rate
Saturation, 23 ℃0.50%ISO 62
Equilibrium, 23 ℃, 50% RH0.20%ISO 62

MECHANICALNominal valueUnitTest method
Tensile modulus
23℃2350MPaISO 527-1-2
tensile strength
Fracture, 23 ℃57.0MPaISO 527-2/50
Yield, 23 ℃58.0MPaISO 527-2/50
Tensile strain
Yield, 23 ℃4.5%ISO 527-2/50
Nominal tensile fracture strain
23℃100%ISO 527-2/50
Bending modulus
23℃2300MPaISO 178
bending strength ISO 178
23℃86.0MPaISO 178
3.50% strain, 23 ℃72.0MPaISO 178

IMPACTNominal valueUnitTest method
Charpy Notched Impact Strength ISO 179/1eA
-30℃30kJ/m²ISO 179/1eA
23℃65kJ/m²ISO 179/1eA
Impact strength of cantilever beam notch ISO 180/A
-30℃30kJ/m²ISO 180-A
23℃60kJ/m²ISO 180-A
Multi axial instrumented impact energy ISO 6603-2
-30℃50.0JISO 6603-2
23℃45.0JISO 6603-2
Multi axial instrumented peak impact force ISO 6603-2
-30℃5200NISO 6603-2
23℃4100NISO 6603-2

THERMALNominal valueUnitTest method
Hot deformation temperature
1.8 MPa, unannealed100ISO 75-2/A
0.45 MPa, unannealed123ISO 75-2/B
Vicat Softening Temp
B120136ISO 306/B120
Linear coefficient of thermal expansion
TD:23~55℃9.0E-51/℃ISO 11359-2
MD:23~55℃8.0E-51/℃ISO 11359-2
Thermal conductivity coefficient
23℃0.20W/m/KISO 8302

Electrical performanceNominal valueUnitTest method
Surface resistivity1.0E+16ohmsIEC 60093
Volume resistivity
23℃1.0E+16ohms·cmIEC 60093
Dielectric strength
23 ℃,1 mm34kV/mmIEC 60243-1
Relative permittivity IEC 60250
23℃,100 Hz3.10 IEC 60250
23℃,1 MHz3.00 IEC 60250
Dissipation factor IEC 60250
23℃,100 Hz2.0E-3 IEC 60250
23℃,1 MHz0.013 IEC 60250
Compared to the leakage tracing index
Solution A225VIEC 60112

FLAME CHARACTERISTICSNominal valueUnitTest method
Flame retardant level UL 94
1.50 mmV-0 UL 94
3.00 mmV-0 5VA UL 94

Notes
1. Typical properties: these are not to be construed as specifications.
2. 600 bar
3. 0.079 in/min
4. Across Flow
【 Disclaimer 】
Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials.