About |
---|
DuPont FEP film is a transparent, thermoplastic film that can be heat sealed, thermoformed, vacuum formed, heat bonded, welded, metalized, laminated – combined with dozens of other materials, and can also be used as an excellent hot-melt adhesive.&& |
Product Description | |
---|---|
Supplier | Chemours |
Generic | FEP |
Material Status | Commercial: Active |
Features | Weather resistance is good,No viscosity,Good heat sealing,High impact resistance,Good Electrical Properties,Low coefficient of friction,Good tear strength,Solvent resistance,Low moisture absorption,VTM-0 |
Availabilitys | North America,Latin America,Asia Pacific,Europe |
Technical Data | |||
---|---|---|---|
PHYSICAL | Nominal value | Unit | Test method |
Density | 2.15 | g/cm³ | ASTM D1505 |
dimensional stability | ASTM D1042 | ||
TD,Shrinkage,150℃ | 2.2 | % | ASTM D1042 |
MD,Expansion,150℃ | 0.72 | % | ASTM D1042 |
Water absorption rate | |||
24hr | < 0.010 | % |
MECHANICAL | Nominal value | Unit | Test method |
---|---|---|---|
friction coefficient | |||
Steel – Dynamic | 0.10 to 0.30 | ASTM D1894 |
film | Nominal value | Unit | Test method |
---|---|---|---|
film thickness | |||
test | 25 | µm | |
tensile strength | ASTM D882 | ||
MD, yield, 25 µ m | 12.0 | MPa | ASTM D882 |
MD, fracture, 25 µ m | 21.0 | MPa | ASTM D882 |
Tensile strain | |||
MD, fracture, 25 µ m | 300 | % | ASTM D882 |
Bending modulus | |||
MD,25 µm | 480 | MPa | ASTM D882 |
Elmandorf tear strength | |||
MD,25 µm | 130 | g | ASTM D1922 |
Graves Tear(25.0 µm) | 3 | N | ASTM D1004 |
IMPACT | Nominal value | Unit | Test method |
---|---|---|---|
Izod notched impact strength | |||
25µm | 77.0 | J/cm | Internal Method |
THERMAL | Nominal value | Unit | Test method |
---|---|---|---|
Hot deformation temperature | ASTM D648 | ||
0.45 MPa, unannealed, 0.0250 mm | 70.0 | ℃ | ASTM D648 |
1.8 MPa, unannealed, 0.0250 mm | 51.0 | ℃ | ASTM D648 |
Melting peak temperature | 260 to 280 | ℃ | ASTM D3418 |
specific heat | |||
25℃ | 1170 | J/kg/℃ | |
Thermal conductivity coefficient | |||
25℃ | 0.20 | W/m/K | Internal Method |
Electrical performance | Nominal value | Unit | Test method |
---|---|---|---|
Surface resistivity | > 1.0E+16 | ohms | ASTM D257 |
Volume resistivity | > 1.0E+18 | ohms·cm | ASTM D257 |
Dielectric strength | ASTM D149 | ||
23 ℃, 0.025 mm, in air | 260 | kV/mm | ASTM D149 |
23 ℃, 5 mm, in air | 70 | kV/mm | ASTM D149 |
Dielectric constant | ASTM D150 | ||
1 kHz | 1.93 to 2.02 | ASTM D150 | |
25 ℃ | 2.00 | ASTM D150 | |
Dissipation factor | ASTM D150 | ||
1 kHz | 2.0E-4 | ASTM D150 | |
1 MHz | 5.0E-4 | ASTM D150 | |
25℃ | 2.0E-4 to 7.0E-4 | ASTM D150 | |
Arc resistance | |||
0.025 mm | > 165 | sec | ASTM D495 |
insulation resistance | Internal Method | ||
100℃ | 3.5E+11 | ohms | Internal Method |
150℃ | 2.5E+11 | ohms | Internal Method |
200℃ | 6.5E+10 | ohms | Internal Method |
FLAME CHARACTERISTICS | Nominal value | Unit | Test method |
---|---|---|---|
Flame retardant level | |||
0.03 mm | VTM-0 | UL 94 | |
Extreme oxygen index | |||
0.025 mm | 95 | % | ASTM D2863 |
optical performance | Nominal value | Unit | Test method |
---|---|---|---|
Refractive index | 1.341 to 1.347 | ASTM D542 | |
Transmittance | |||
25.0 µm | 96.0 | % | ASTM E424 |
Supplementary information | Nominal value | Unit | Test method |
---|---|---|---|
Burst Strength(Mullen,25.0 µm) | 0.0760 | MPa | ASTM D774 |
MIT flexural strength (film, 25.0 µ m) | 1.0E+4 | Cycles | ASTM D2176 |
Permeability | |||
Gas: Carbon dioxide | 25900 | cm³/m²/atm/24 hr | ASTM D1434 |
Gas: Hydrogen | 34100 | cm³/m²/atm/24 hr | ASTM D1434 |
Gas: Nitrogen | 5000 | cm³/m²/atm/24 hr | ASTM D1434 |
Gas: Oxygen | 11600 | cm³/m²/atm/24 hr | ASTM D1434 |
Vapor: Acetic Acid | 6.3 | g/m²/24 hr | ASTM E96 |
Vapor: Acetone | 15 | g/m²/24 hr | ASTM E96 |
Vapor: Benzene | 9.9 | g/m²/24 hr | ASTM E96 |
Vapor: Carbon Tetrachloride | 4.8 | g/m²/24 hr | ASTM E96 |
Vapor: Ethyl Alcohol | 11 | g/m²/24 hr | ASTM E96 |
Vapor: Hexane | 8.7 | g/m²/24 hr | ASTM E96 |
Vapor: Water | 7.0 | g/m²/24 hr | ASTM E96 |
Notes |
---|
1. Typical properties: these are not to be construed as specifications. |
2. -40 to 240°C |
3. 500 V/sec, Method A (Short-Time) |
4. 6.35mm diameter electrode, 0.79mm radius, 60Hz |
5. -40 to 225°C |
6. 100Hz to 1MHz |
7. Samples melted in arc did not track. |
8. Based upon 0.2 MF wound capacitor sections, using single laer, Teflon® 50A Film. |
【 Disclaimer 】 Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials. |