| About |
|---|
| Ultramid B3M8 (8260) is a 40% mineral reinforced PA6 injection molding compound. It possesses high stiffness, dimensional stability and heat resistance combined with excellent processability including low warp and resistance to sink-mark formation. It is also available in heat stabilized (Ultramid B3WM8) versions. It can be painted or chrome plated and is also available in pigmented versions.&& |
| Product Description | |
|---|---|
| Supplier | BASF |
| Generic | PA6 |
| Material Status | Commercial: Active |
| Features | Good Rigidity,Low warping,Excellent Processability,Good Dimensional Stability,Sprayable,High Heat Resistance |
| Availabilitys | North America |
| Process Methods | Injection Molding |
| Technical Data | |||
|---|---|---|---|
| PHYSICAL | Nominal value | Unit | Test method |
| Density | 1.49 | g/cm³ | ASTM D792 |
| Density | 1.49 | g/cm³ | ISO 1183 |
| Shrinkage rate | |||
| MD:3.2 mm | 0.90 | % | |
| Water absorption rate | |||
| Saturation, 23 ℃ | 5.7 | % | ISO 62 |
| saturated | 5.7 | % | ASTM D570 |
| Equilibrium, 23 ℃, 50% RH | 1.6 | % | ISO 62 |
| Balance, 50% RH | 1.6 | % | ASTM D570 |
| 24hr | 1.1 | % | ASTM D570 |
| 23℃,24hr | 1.1 | % | ISO 62 |
| IMPACT | Nominal value | Unit | Test method |
|---|---|---|---|
| Charpy Notched Impact Strength | ISO 179 | ||
| -30℃ | 3.0 | kJ/m² | ISO 179 |
| 23℃ | 3.0 | kJ/m² | ISO 179 |
| Charpy Unnotch Impact strength | |||
| 23℃ | 120 | kJ/m² | ISO 179 |
| Impact strength of cantilever beam notch | |||
| 23℃ | 53 | J/m | ASTM D256 |
| THERMAL | Nominal value | Unit | Test method |
|---|---|---|---|
| Hot deformation temperature | |||
| 0.45 MPa, unannealed | 195 | ℃ | ISO 75-2/B |
| Melting peak temperature | 220 | ℃ | ASTM D3418 |
| Melting temperature | |||
| DSC | 220 | ℃ | ISO 3146 |
| Linear coefficient of thermal expansion | |||
| TD | 5.8E-5 | 1/℃ | |
| MD | 4.6E-5 | 1/℃ | |
| MD | 5.0E-5 | 1/℃ | ASTM E831 |
| Electrical performance | Nominal value | Unit | Test method |
|---|---|---|---|
| Volume resistivity | > 1.0E+15 | ohms·cm | IEC 60093 |
| 1.50 mm | > 1.0E+15 | ohms·cm | ASTM D257 |
| Dielectric strength | |||
| 1.5 mm | 22 | kV/mm | ASTM D149 |
| Supplementary information | Nominal value | Unit | Test method |
|---|---|---|---|
| Drop hammer impact | |||
| 23℃ | 6.78 | J | Internal Method |
| MECHANICAL | Nominal value | Unit | Test method |
|---|---|---|---|
| Tensile modulus | ISO 527-2 | ||
| -40℃ | 8310 | MPa | ISO 527-2 |
| 23℃ | 6400 | MPa | ISO 527-2 |
| 80℃ | 1360 | MPa | ISO 527-2 |
| 120℃ | 970 | MPa | ISO 527-2 |
| 150℃ | 910 | MPa | ISO 527-2 |
| tensile strength | |||
| Fracture, 23 ℃ | 90.0 | MPa | ASTM D638 |
| Fracture, 23 ℃ | 85.0 | MPa | ISO 527-2 |
| Tensile strain | |||
| Fracture, 23 ℃ | 10 | % | ISO 527-2 |
| Fracture, 23 ℃ | 10 | % | ASTM D638 |
| Bending modulus | ASTM D790 | ||
| 23℃ | 5200 | MPa | ISO 178 |
| -40℃ | 5860 | MPa | ASTM D790 |
| 23℃ | 5760 | MPa | ASTM D790 |
| 65℃ | 1540 | MPa | ASTM D790 |
| 90℃ | 810 | MPa | ASTM D790 |
| 121℃ | 815 | MPa | ASTM D790 |
| bending strength | ASTM D790 | ||
| 23℃ | 140 | MPa | ISO 178 |
| -40℃ | 207 | MPa | ASTM D790 |
| 23℃ | 138 | MPa | ASTM D790 |
| 65℃ | 55.0 | MPa | ASTM D790 |
| 90℃ | 35.0 | MPa | ASTM D790 |
| 121℃ | 34.0 | MPa | ASTM D790 |
| Rockwell hardness | |||
| R-level | 119 | ASTM D785 |
| Process Conditions | |||
|---|---|---|---|
| injection | Nominal value | Unit | Test method |
| Drying temperature | 83 | °C | |
| Drying time | 2.0 to 4.0 | hr | |
| Recommended maximum moisture content | 0.15 | % | |
| Processing (melt) temperature | 270 to 295 | °C | |
| Mold temperature | 80 to 95 | °C | |
| Injection pressure | 3.50 to 12.5 | MPa | |
| Injection speed | Fast | ||
| Notes |
|---|
| 【 Disclaimer 】 Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials. |