About |
---|
30% Glass fiber filled, standard flow Polyetherimide (Tg 217C). ECO Conforming, UL94 V0 and 5VA listing. NSF 51 listing, WRAS certification, KTW certification in recognized colors.&& |
Product Description | |
---|---|
Supplier | SABIC |
Generic | Polyetherimide |
Material Status | Commercial: Active |
Features | ECO,V-0,5VA |
Availabilitys | North America,Asia Pacific,Europe |
Process Methods | Injection Molding |
Technical Data | |||
---|---|---|---|
PHYSICAL | Nominal value | Unit | Test method |
Density | 1.51 | g/cm³ | ASTM D792 |
Melt Flow Rate | |||
337℃,6.60kg | 5.0 | g/10min | ASTM D1238 |
Shrinkage rate | |||
TD:3.2 mm | 0.20 to 0.40 | % | Internal Method |
MD:3.2 mm | 0.20 to 0.40 | % | Internal Method |
Water absorption rate | |||
Equilibrium, 23 ℃ | 0.90 | % | ASTM D570 |
24hr | 0.16 | % | ASTM D570 |
IMPACT | Nominal value | Unit | Test method |
---|---|---|---|
Impact strength of cantilever beam notch | |||
3.2mm | 490 | J/m | ASTM D256 |
THERMAL | Nominal value | Unit | Test method |
---|---|---|---|
Hot deformation temperature | |||
1.8 MPa, unannealed, 6.4 mm | 210 | ℃ | ASTM D648 |
0.45 MPa, unannealed, 6.4 mm | 212 | ℃ | ASTM D648 |
Vicat Softening Temp | 228 | ℃ | ASTM D1525 5 |
Linear coefficient of thermal expansion | |||
MD:-20~150℃ | 2.0E-5 | 1/℃ | ASTM E831 |
Relative temperature index | |||
Electrical performance | 180 | ℃ | UL 746 |
Strength mechanical performance | 180 | ℃ | UL 746 |
Impact mechanical performance | 170 | ℃ | UL 746 |
Electrical performance | Nominal value | Unit | Test method |
---|---|---|---|
Volume resistivity | 3.0E+16 | ohms·cm | ASTM D257 |
Dielectric strength | ASTM D149 | ||
1.6 mm in air | 25 | kV/mm | ASTM D149 |
1.6 mm in oil | 30 | kV/mm | ASTM D149 |
Dielectric constant | |||
1 kHz | 3.70 | ASTM D150 | |
Dissipation factor | ASTM D150 | ||
1 kHz | 1.5E-3 | ASTM D150 | |
2.45 GHz | 5.3E-3 | ASTM D150 | |
Arc resistance | PLC 6 | ASTM D495 | |
Compared to the leakage tracing index | PLC 4 | UL 746 | |
High Arc Burning Index (HAI) | PLC 4 | UL 746 | |
High voltage arc marking rate | |||
HVTR | PLC 3 | UL 746 | |
Hot wire ignition | |||
HWI | PLC 1 | UL 746 |
FLAME CHARACTERISTICS | Nominal value | Unit | Test method |
---|---|---|---|
Flame retardant level | UL 94 | ||
0.25 mm | V-0 | UL 94 | |
1.20 mm | 5VA | UL 94 | |
Extreme oxygen index | 50 | % | ASTM D2863 |
NBS smoke density | |||
Flaming,Ds,4 min | 1.60 | ASTM E662 |
MECHANICAL | Nominal value | Unit | Test method |
---|---|---|---|
Tensile modulus | 9310 | MPa | ASTM D638 |
tensile strength | |||
fracture | 159 | MPa | ASTM D638 |
yield | 169 | MPa | ASTM D638 |
Tensile strain | |||
fracture | 3.0 | % | ASTM D638 |
Bending modulus | |||
100 mm span | 8960 | MPa | ASTM D790 |
bending strength | |||
Fracture, 100 mm span | 228 | MPa | ASTM D790 |
Rockwell hardness | |||
M-level | 114 | ASTM D785 |
Process Conditions | |||
---|---|---|---|
injection | Nominal value | Unit | Test method |
Drying temperature | 149 | °C | |
Drying time | 4.0 to 6.0 | hr | |
Drying time, maximum | 24 | hr | |
Recommended maximum moisture content | 0.020 | % | |
Recommended injection volume | 40 to 60 | % | |
Barrel rear temperature | 332 to 399 | °C | |
Barrel middle temperature | 338 to 399 | °C | |
Barrel front temperature | 343 to 399 | °C | |
Nozzle temperature | 343 to 399 | °C | |
Processing (melt) temperature | 349 to 399 | °C | |
Mold temperature | 135 to 163 | °C | |
Back pressure | 0.345 to 0.689 | MPa | |
Screw speed | 40 to 70 | rpm | |
Vent depth | 0.025 to 0.076 | mm |
Notes |
---|
1. Typical properties: these are not to be construed as specifications. |
2. 0.20 in/min |
3. Type I, 0.20 in/min |
4. 0.10 in/min |
5. Rate A (50°C/h), Loading 2 (50 N) |
6. Tungsten Electrode |
7. Surface |
8. 4 min |
【 Disclaimer 】 Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials. |