FLEX NORYL™ Resin WCD891B

About
Non-halogenated flame retardant, flexible NORYL resin intended for evaluation in wire and cable applications. Strong flame retardant performance capable of meeting VW-1 and 80°C end use temperature requirements as defined by UL 1581. 89 Shore A hardness. Good processing by using standard extrusion equipment. UL1581 tests conducted on 2.0 mm wire with 0.12 mm x 20 stranded copper conductor.&&

Product Description
SupplierSABIC
GenericPPO(PPE)+TPE
Material StatusCommercial: Active
FeaturesGood flexibility,Halogen free,Flame Characteristics
AvailabilitysNorth America

Technical Data
PHYSICALNominal valueUnitTest method
Density1.10g/cm³ASTM D792
Melt Flow Rate
250℃,5.0kg20g/10minASTM D1238

elastic bodyNominal valueUnitTest method
tear strength7.0kN/mISO 6383

THERMALNominal valueUnitTest method
Embrittlement temperature< -40.0ASTM D746
UL temperature rating80UL 1581
Heat Deformation(100℃)9.0%UL 1581

Electrical performanceNominal valueUnitTest method
Surface resistivity5.1E+15ohmsASTM D257
Volume resistivity1.5E+15ohms·cmASTM D257
Dielectric strength
2 mm in oil24kV/mmIEC 60243-1
Relative permittivity
1 MHz2.90 IEC 60250
Dissipation factor
1 MHz0.040 IEC 60250
Compared to the leakage tracing index600VIEC 60112

FLAME CHARACTERISTICSNominal valueUnitTest method
4.00 mmV-0 UL 94
Glowing wire flammability index
3.0 mm850IEC 60695-2-12
Igniting temperature of the hot wire
3 mm750IEC 60695-2-13
Extreme oxygen index27%ISO 4589-2
VW-1Pass UL 1581

MECHANICALNominal valueUnitTest method
Shore hardness
Shore A, 30 seconds89 ASTM D2240
tensile strength
fracture18.0MPaUL 1581
fracture16.0MPaASTM D638
Fracture, 113 ℃21.0MPaUL 1581
fracture15.0MPaISO 527-2/50
Tensile strain
yield140%ISO 527-2/50
fracture220%UL 1581
fracture170%ASTM D638
Fracture, 113 ℃160%UL 1581
Bending modulus
100 mm span160MPaASTM D790
140MPaISO 178

Process Conditions
Squeeze descriptionNominal valueUnitTest method

Notes
1. Typical properties: these are not to be construed as specifications.
2. 2.0 mm wire with 0.12 mm x 20 stranded copper
3. Type I, 2.0 in/min
4. After 7 days. Tested on 2.0 mm wire with 0.12 mm x 20 stranded copper
5. 6 days, 2.0 mm wire with 0.12 mm x 20 stranded copper
6. 0.49 in/min
7. 2.0mm wire with 0.12 mm x 20 stranded copper
8. 250g, 2.0 mm wire with 0.12 mm x 20 stranded copper
【 Disclaimer 】
Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials.