NANCAR® 4155

About
NANCAR® 4155 is a high acrylonitrile butadiene copolymer with excellent oil resistance. It is polymerized at low temperature and contains sufficient antioxidant for normal aging conditions. It has fast curing rate, low mold fouling and superior resilience properties. It has good processing characteristics in compounds where flow and knitting are desired and is especially valuable in high durometer compounds. NANCAR® 4155 provides good processing and building tack. It is suggested for use in molded goods, friction stock and similar applications.&&

Product Description
SupplierNantex
GenericNBR
Material StatusCommercial: Active
FeaturesExcellent Processability,Good liquidity,Inoxidizability,Elastic,Copolymer,Grease resistance,Fast Cure
AvailabilitysAsia Pacific

Technical Data
PHYSICALNominal valueUnitTest method
Density1.00g/cm³
Mooney viscosity ASTM D1646
ML 1+4,100℃51MUASTM D1646
ML 1+4,100℃78MUASTM D1646
Acrylonitrile content (Bound)40.0%Internal Method
StabilizerNon-staining 
solubility
in MEK100%

MECHANICALNominal valueUnitTest method
Shore hardness ASTM D2240
Shore A, 5 seconds76 ASTM D2240
Shore A, 5 seconds77 ASTM D2240
Shore A, 5 seconds78 ASTM D2240

elastic bodyNominal valueUnitTest method
tensile strength ASTM D412
300% strain10.9MPaASTM D412
300% strain12.8MPaASTM D412
300% strain13.3MPaASTM D412
tensile strength ASTM D412
yield26.4MPaASTM D412
yield26.8MPaASTM D412
yield26.0MPaASTM D412
Tensile strain ASTM D412
fracture590%ASTM D412
fracture540%ASTM D412
fracture520%ASTM D412
tear strength58.0kN/mASTM D624
Compression deformation
100℃,70 hr59%ASTM D395

Aging performanceNominal valueUnitTest method
The rate of change in tensile strength in air
100℃,70 hr-1.0%ASTM D573
The rate of change in ultimate elongation in air
100℃,70 hr-22%ASTM D573
The rate of change in hardness of a hardness tester in the air
Shore A, 100 ℃, 70 hr5.0 ASTM D573
The rate of change in tensile strength ASTM D471
100 ℃, 70 hr, in ASTM # 1 oil-11%ASTM D471
100 ℃, 70 hr, in IRM 903 oil-26%ASTM D471
Change rate of ultimate elongation ASTM D471
100 ℃, 70 hr, in ASTM # 1 oil-28%ASTM D471
100 ℃, 70 hr, in IRM 903 oil-28%ASTM D471
The rate of change in Shore hardness ASTM D471
Support A, 100 ℃, 70 hr, in ASTM # 1 oil3.0 ASTM D471
Support A, 100 ℃, 70 hr, in IRM 903 oil-5.0 ASTM D471
Volume change ASTM D471
100 ℃, 70 hr, ASTM standard oil (No.1)-0.20%ASTM D471
100 ℃, 70 hr, in IRM 903 oil8.5%ASTM D471

THERMALNominal valueUnitTest method
Heat loss0.30%ASTM D5688

Notes
【 Disclaimer 】
Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials.