Hostaform® C 9021 K

About
Chemical abbreviation according to ISO 1043-1: POM Molding compound ISO 9988- POM-K, M-GNR, 03-002, K5 POM copolymer Injection molding type, with special chalk modified; good wear properties; good chemical resistance to solvents, fuel and strong alkalis as well as good hydrolysis resistance; high resistance to thermal and oxidative degradation. UL-registration in natural and a thickness more than 1.57 mm as UL 94 HB, temperature index UL 746 B electrical 105 °C, mechanical 90 °C (tensile impact) and 80 °C (tensile). Burning rate ISO 3795 and FMVSS 302 < 100 mm/min for a thickness more than 1 mm. Ranges of applications: for unlubricated or once-only-lubricant sliding Parts. FMVSS = Federal Motor Vehicle Safety Standard (USA) UL = Underwriters Laboratories (USA)&&

Product Description
SupplierCelanese
GenericCopolymer Polyformaldehyde
Material StatusCommercial: Active
FeaturesGood Rigidity,Weather resistance is good,High impact resistance,High Heat Resistance,Good tear strength,HB
AvailabilitysNorth America,Asia Pacific,Europe
Process MethodsInjection Molding

Technical Data
MECHANICALNominal valueUnitTest method
Tensile modulus3000MPaISO 527-2/1A/1
tensile strength
yield60.0MPaISO 527-2/1A/50
Tensile strain
yield8.0%ISO 527-2/1A/50
Nominal tensile fracture strain22%ISO 527-2/1A/50
Tensile creep modulus ISO 899-1
1 hr2500MPaISO 899-1
1000 hr1400MPaISO 899-1
Bending modulus
23℃2900MPaISO 178

IMPACTNominal valueUnitTest method
Charpy Notched Impact Strength ISO 179/1eA
-30℃5.0kJ/m²ISO 179/1eA
23℃5.0kJ/m²ISO 179/1eA
Charpy Unnotch Impact strength ISO 179/1eU
-30℃100kJ/m²ISO 179/1eU
23℃100kJ/m²ISO 179/1eU

THERMALNominal valueUnitTest method
Hot deformation temperature
1.8 MPa, unannealed100ISO 75-2/A
Melting temperature166ISO 11357-3
Linear coefficient of thermal expansion
MD1.1E-41/℃ISO 11359-2

Electrical performanceNominal valueUnitTest method
Surface resistivity1.0E+14ohmsIEC 60093
Volume resistivity1.0E+14ohms·cmIEC 60093
Dielectric strength35kV/mmIEC 60243-1
Relative permittivity IEC 60250
100 Hz4.20 IEC 60250
1 MHz4.20 IEC 60250
Dissipation factor IEC 60250
100 Hz2.5E-3 IEC 60250
1 MHz6.0E-3 IEC 60250
Compared to the leakage tracing index600VIEC 60112

FLAME CHARACTERISTICSNominal valueUnitTest method
Flame retardant level UL 94
1.60 mmHB UL 94
3.20 mmHB UL 94

PHYSICALNominal valueUnitTest method
Density1.44g/cm³ISO 1183
Melt Volume Rate
190℃,2.16 kg7.50cm³/10minISO 1133
Shrinkage rate ISO 294-4
TD1.8%ISO 294-4
MD2.0%ISO 294-4
Water absorption rate
Saturation, 23 ℃0.65%ISO 62
Density of Melt1.230g/cm³Internal Method
Specific Heat Capacity of Melt2060J/kg/℃Internal Method
Thermal Conductivity of Melt0.20W/m/KInternal Method

Process Conditions
injectionNominal valueUnitTest method
Drying temperature100 to 120°C
Drying time3.0 to 4.0hr
Recommended maximum moisture content0.15%
Hopper temperature20 to 30°C
Barrel rear temperature170 to 180°C
Barrel middle temperature180 to 190°C
Barrel front temperature190 to 200°C
Nozzle temperature190 to 210°C
Processing (melt) temperature190 to 210°C
Mold temperature80 to 120°C
Injection pressure60.0 to 120MPa

Notes
1. Typical properties: these are not to be construed as specifications.
2. 30s
3. 10°C/min
【 Disclaimer 】
Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials.