About |
---|
Stanyl®是我们的高性能聚酰胺46,可应用于汽车、电子电气、齿轮、和户外动力设备。&&Stanyl®作为高性能聚酰胺,在对耐热性、设计硬度、摩擦磨耗以及流动性都有要求的严苛的应用中表现无与伦比。&&Stanyl®能在高达220°C时依旧保持良好的机械性能,这使它比PPA、PA6T、PA9T、PPS 和LCP更适合超高性能应用. |
Product Description | |
---|---|
Supplier | DSM |
Generic | PA 46 |
Material Status | Commercial: Active |
Features | Food contact compliance,Electroplating,Heat Resistance, Good,Heat Stabilized |
Technical Data | |||
---|---|---|---|
PHYSICAL | Nominal value | Unit | Test method |
Density | 1.41 | g/cm³ | ISO 1183 |
Shrinkage rate | |||
MD | 1.3 / * | % | ISO 294-4 |
Spiral flow length 1.0 mm 800 bar | 100 / * | mm | – |
Spiral flow length 1.0 mm 900 bar | 110 / * | mm | – |
Spiral flow length 1.0 mm 1000 bar | 120 / * | mm | – |
MECHANICAL | Nominal value | Unit | Test method |
---|---|---|---|
Tensile modulus | 10000 / 6000 | MPa | ISO 527-1-2 |
Tensile modulus | |||
180℃ | 4400 / * | MPa | ISO 527-1-2 |
Tensile modulus, low thickness | 10000 / – | MPa | ISO 527-1/-2 |
Tensile modulus (test thickness) | 1 / – | mm | ISO 527-1/-2 |
Fracture stress | 210 / 115 | MPa | ISO 527-1/-2 |
Fracture stress (120 ° C) | 110 / – | MPa | ISO 527-1/-2 |
Fracture stress (160 ° C) | 100 / * | MPa | ISO 527-1/-2 |
Tensile stress (180 ° C) | 95 / * | MPa | ISO 527-1/-2 |
Tensile stress (200 ° C) | 90 / * | MPa | ISO 527-1/-2 |
Fracture stress (low thickness) | 196 / – | MPa | ISO 527-1/-2 |
Fracture strain (test thickness) | 1 / – | mm | ISO 527-1/-2 |
Tensile strain | |||
fracture | 4 / 7 | % | ISO 527-1/2 |
Fracture strain (120 ° C) | 7.5 / – | % | ISO 527-1/-2 |
Fracture strain (160 ° C) | 7.5 / * | % | ISO 527-1/-2 |
Fracture strain (180 ° C) | 7.5 / * | % | ISO 527-1/-2 |
Fracture strain (200 ° C) | 7.5 / * | % | ISO 527-1/-2 |
Bending modulus | 9000 / 5500 | MPa | ISO 178 |
Bending modulus | |||
120℃ | 4700 / * | MPa | ISO 178 |
bending strength | 300 / 180 | MPa | ISO 178 |
bending strength | |||
160℃ | 130 / * | MPa | ISO 178 |
Weld seam strength (thickness 1) | 109 / – | MPa | ISO 527-1/-2 |
Elongation rate of weld seam (thickness 1) | 1.4 / – | % | ISO 527-1/-2 |
Thickness testing | 1 / * | mm | ISO 527-1/-2 |
Electrical performance | Nominal value | Unit | Test method |
---|---|---|---|
Relative permittivity | |||
100 Hz | 4.4 / 12 | IEC 60250 | |
Dissipation factor | |||
100 Hz | 230 / 900 | E-4 | IEC 60250 |
Volume resistivity | >1E15 | ohms·cm | IEC 60093 |
Dielectric strength | 35 / 25 | kV/mm | IEC 60243-1 |
Compared to the leakage tracing index | 500 / – | V | IEC 60112 |
Other performance | Nominal value | Unit | Test method |
---|---|---|---|
Water absorption rate | 9.5 / * | % | ISO 62 |
Water absorption rate | |||
23 ℃, 24 hours, in water | 2.65 / * | % | ISO 62 |
Moisture absorption rate | 2.6 / * | % | Sim. to ISO 62 |
Material characteristics | Nominal value | Unit | Test method |
---|---|---|---|
Viscosity number | 145 / * | cm³/g | ISO 307, 1157, 1628 |
IMPACT | Nominal value | Unit | Test method |
---|---|---|---|
Charpy Unnotch Impact strength | |||
23℃ | 80 / 100 | kJ/m² | ISO 179/1eU |
Charpy Notched Impact Strength | |||
23℃ | 12 / 21 | kJ/m² | ISO 179/1eA |
Impact strength of cantilever beam notch | |||
23℃ | 12 / 21 | kJ/m² | ISO 180-1A |
THERMAL | Nominal value | Unit | Test method |
---|---|---|---|
Melting temperature | |||
10℃ / min | 295 / * | ℃ | ISO 11357-1/-3 |
Glass transition temperature | |||
10℃/min | 75 / * | °C | ISO 11357-1/-2 |
Hot deformation temperature | |||
1.8 MPa | 290 / * | ℃ | ISO 75-1/2 |
Vicat Softening Temp | |||
B50 | 290 / * | ℃ | ISO 306 |
Linear coefficient of thermal expansion | |||
TD | 0.25E-4 | /℃ | ISO 11359-1/-2 |
Combustibility (1.5mm thickness) | HB / * | class | IEC 60695-11-10 |
Test thickness | 1.6 / * | mm | IEC 60695-11-10 |
UL certification | Yes / * | – | – |
Combustibility at a thickness of h | HB / * | class | IEC 60695-11-10 |
The thickness of the test specimen used for testing | 0.9 / * | mm | IEC 60695-11-10 |
Extreme oxygen index | 22 / * | % | ISO 4589-1/-2 |
Glow wire combustion index GWFI | 925 / – | °C | IEC 60695-2-12 |
GWFI (thickness (1)) | 3 / – | mm | IEC 60695-2-12 |
Glow wire combustion index GWFI | 675 / – | °C | IEC 60695-2-12 |
GWFI (thickness (2)) | 0.75 / – | mm | IEC 60695-2-12 |
Glow wire ignition temperature GWIT | 725 / – | °C | IEC 60695-2-13 |
GWIT (thickness (1)) | 3 / – | mm | IEC 60695-2-13 |
Glow wire ignition temperature GWIT | 700 / – | °C | IEC 60695-2-13 |
GWIT (thickness (2)) | 0.75 / – | mm | IEC 60695-2-13 |
Heat index 2500 hours | 171 / * | °C | IEC 60216/ISO 527-1/-2 |
Heat index 5000 hours | 159 / * | °C | IEC 60216/ISO 527-1/-2 |
Heat index 10000 hours | 147 / * | °C | IEC 60216/ISO 527-1/-2 |
Heat index 20000 hours | 137 / * | °C | IEC 60216/ISO 527-1/-2 |
Melt density | 1280 / * | kg/m³ | – |
Melt thermal conductivity | 0.28 / * | W/(m K) | – |
Specific heat of melt | 2430 / * | J/(kg K) | – |
Thermal diffusivity | 9.02E-8 / * | m²/s | – |
Notes |
---|
【 Disclaimer 】 Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials. |