| About |
|---|
| Versaflex™ CL2250 is an easy processing compound designed for use in injection molding applications where FDA compliance, clarity and enhanced heat resistance are required. Excellent Clarity Overmold Adhesion to Polypropylene Superior Colorability Very Good Heat and Boil Resistance&& |
| Product Description | |
|---|---|
| Supplier | Polyone |
| Generic | TPE |
| Material Status | Commercial: Active |
| Features | Excellent Processability,Good Clarity,Good coloring |
| Availabilitys | Africa & Middle East ,North America,Latin America,Asia Pacific |
| Process Methods | Injection Molding |
| Technical Data | |||
|---|---|---|---|
| elastic body | Nominal value | Unit | Test method |
| tensile strength | ASTM D412 | ||
| Fracture, 23 ℃ | 5.70 | MPa | ASTM D412 |
| 100% strain, 23 ℃ | 1.52 | MPa | ASTM D412 |
| 300% Strain, 73°F | 2.32 | MPa | ASTM D412 |
| Tensile strain | |||
| Fracture, 23 ℃ | 770 | % | ASTM D412 |
| tear strength | 24.5 | kN/m | ASTM D624 |
| Compression deformation | |||
| 23℃,22 hr | 20 | % | ASTM D395B |
| MECHANICAL | Nominal value | Unit | Test method |
|---|---|---|---|
| Shore hardness | |||
| Shore A, 10 seconds | 50 | ASTM D2240 | |
| Bending modulus | 13.9 | MPa | ASTM D790 |
| PHYSICAL | Nominal value | Unit | Test method |
|---|---|---|---|
| Density | 0.888 | g/cm³ | ASTM D792 |
| Melt Flow Rate | |||
| 190℃,2.16kg | 13 | g/10min | ASTM D1238 |
| Shrinkage rate | |||
| MD | 0.80 to 1.2 | % | ASTM D955 |
| Apparent viscosity of melt | |||
| 200℃,11200 sec^-1 | 11.9 | Pa·s | ASTM D3835 |
| Process Conditions | |||
|---|---|---|---|
| injection | Nominal value | Unit | Test method |
| Proposed maximum recycled material ratio | 20 | % | |
| Barrel rear temperature | 171 to 188 | °C | |
| Barrel middle temperature | 193 to 221 | °C | |
| Barrel front temperature | 193 to 227 | °C | |
| Nozzle temperature | 210 to 227 | °C | |
| Processing (melt) temperature | 210 to 221 | °C | |
| Mold temperature | 13 to 38 | °C | |
| Back pressure | 0.00 to 0.552 | MPa | |
| Screw speed | 25 to 75 | rpm | |
| Notes |
|---|
| 1. Please contact GLS Thermoplastic Elastomers for a copy of the FDA compliance letter. |
| 2. Please contact PolyOne GLS Thermoplastic Elastomers for a complete copy of the GLS Healthcare Policy. 1. The Customer must notify GLS of any FDA Class I and/or European Union Class I medical devices for each specific product and application. 2. The Customer shall not knowingly manufacture, use, sell or otherwise supply, directly or indirectly products or compounds made from GLS products in any of the following without prior written approval by GLS for each specific product or application: a. Cosmetics b. Drugs and other Pharmaceuticals c. Temporary or permanent implantation in the human body, regardless of the intended duration of implantation d. Class II and Class III Medical Devices as defined in 21 CFR 860.3 (“Medical Devices”) e. Class IIa, IIb and III as defined in Directive 93/42/EEC |
| 3. Typical properties: these are not to be construed as specifications. |
| 4. Die C |
| 5. 2 hr |
| 【 Disclaimer 】 Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials. |