| About |
|---|
| GETILAN : is the trade-mark of our crosslinkable polyolefinic compounds. GETILAN GPE/134 : high density chemically crosslinkable polythene for insulated cables. It is a conveniently grafted polythene able to react in presence of moisture and of a catalyst. We normally suggest our catalyst type MAC/203 HSL or MAC/100 HS REACTION BETWEEN GRAFTING AND CATALYST: These two compounds, separately stored, must be mixed before starting extrusion in the ratio: GRAFTING/CATALYST 96/4 Certify : ISO 6722 Class D*, SAE J1127/J1128&& |
| Product Description | |
|---|---|
| Generic | XLPE |
| Material Status | Commercial: Active |
| Features | Crosslinked,High density |
| Availabilitys | Europe |
| Process Methods | Extrusion |
| Technical Data | |||
|---|---|---|---|
| PHYSICAL | Nominal value | Unit | Test method |
| Density | 0.940 | g/cm³ | ASTM D792 |
| Melt Flow Rate | |||
| 190℃,5.0kg | 0.20 to 0.60 | g/10min | ASTM D1238 |
| MECHANICAL | Nominal value | Unit | Test method |
|---|---|---|---|
| tensile strength | |||
| yield | 20.0 | MPa | IEC 60811 |
| Tensile strain | |||
| fracture | 450 | % | IEC 60811 |
| Aging performance | Nominal value | Unit | Test method |
|---|---|---|---|
| The rate of change in tensile strength in air | |||
| 175℃,240 hr | 10 | % | ISO 6722 |
| Changes in tensile stress during fracture in air | |||
| 175℃,240 hr | -20 | % | ISO 6722 |
| THERMAL | Nominal value | Unit | Test method |
|---|---|---|---|
| thermosetting | IEC 60811 | ||
| 200℃ | % | ||
| Residual:200℃ | 0.0 | % |
| Electrical performance | Nominal value | Unit | Test method |
|---|---|---|---|
| Volume resistivity | > 1.0E+16 | ohms·cm | BS 6622 |
| Process Conditions | |||
|---|---|---|---|
| Extrusion | Nominal value | Unit | Test method |
| Barrel 1 zone temperature | 165 | °C | |
| Barrel 2 zone temperature | 180 | °C | |
| Barrel 3 zone temperature | 190 | °C | |
| Barrel 4 zone temperature | 205 | °C | |
| Head temperature | 210 | °C | |
| Nozzle temperature | 225 | °C | |
| Notes |
|---|
| 1. Typical properties: these are not to be construed as specifications. |
| 2. 20 N/cm² |
| 3. Test Method: ISO 6722 Class D |
| 【 Disclaimer 】 Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials. |