About |
---|
Hostacom G3 N01 L is a 30% glass fiber reinforced PP homopolymer, with low melt flow, high stiffness, low CLTE (Coefficient of Linear Thermal Expansion) and low creep under load at elevated temperatures. Product is UL listed in all colors. This grade is delivered in natural color version.&& |
Product Description | |
---|---|
Supplier | LyondellBasell |
Generic | PP homopolymerization |
Material Status | Commercial: Active |
Features | Good Rigidity,Low CLTE,Good flexibility,Low liquidity,Homopolymer,HB |
Availabilitys | Europe |
Process Methods | Injection Molding |
Technical Data | |||
---|---|---|---|
PHYSICAL | Nominal value | Unit | Test method |
Density | 1.15 | g/cm³ | ISO 1183/A |
Melt Flow Rate | |||
230℃,5.0kg | 5.0 | g/10min | ISO 1133 |
Melt Volume Rate | |||
230℃,5 kg | 5.00 | cm³/10min | ISO 1133 |
MECHANICAL | Nominal value | Unit | Test method |
---|---|---|---|
Tensile modulus | |||
23℃ | 6500 | MPa | ISO 527-2 |
Tensile strain | |||
fracture | 3.0 | % | ISO 527-2 |
IMPACT | Nominal value | Unit | Test method |
---|---|---|---|
Charpy Notched Impact Strength | |||
23℃ | 9.0 | kJ/m² | ISO 179/1eA |
Charpy Unnotch Impact strength | |||
23℃ | 40 | kJ/m² | ISO 179/1eU |
THERMAL | Nominal value | Unit | Test method |
---|---|---|---|
Hot deformation temperature | |||
0.45 MPa, unannealed | 155 | ℃ | ISO 75-2/B |
1.8 MPa, unannealed | 140 | ℃ | ISO 75-2/A |
Vicat Softening Temp | 130 | ℃ | ISO 306/B |
FLAME CHARACTERISTICS | Nominal value | Unit | Test method |
---|---|---|---|
Flame retardant level | UL 94 | ||
1.50 mm | HB | UL 94 | |
3.00 mm | HB | UL 94 |
Notes |
---|
1. Typical properties: these are not to be construed as specifications. |
【 Disclaimer 】 Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials. |