About |
---|
Thermoplastic, low-smoke, halogen-free, flame retardant compound for cable insulation and sheathing. A flame-retardant low-smoke thermoplastic compound which has been specially developed to meet the requirements of limited toxic/corrosive fume emission, and having high fire retardance as indicated by a high oxygen index. TP543C has been specially developed to comply with the requirements of BS7655 Section 6 for types LTS1,2,3 and 4; EN 50290-2-27 for type HM2 and HD 604 for type HM4. Cables made with TP543C have complied with IEC 332 part 1 and 3 fire tests. TP543C is available in the following versions: TP543CN (natural colour) TP543CB (coloured black) TP543CNU (with a non-staining UV stabiliser added) TP543CBU (carbon black added to give UV&& |
Product Description | |
---|---|
Generic | PE |
Material Status | Commercial: Active |
Features | Weather resistance is good,Low smoke,Halogen free,Flame Characteristics |
Availabilitys | Africa & Middle East ,North America,Latin America,Asia Pacific,Europe |
Process Methods | Extrusion |
Technical Data | |||
---|---|---|---|
PHYSICAL | Nominal value | Unit | Test method |
Density | 1.54 | g/cm³ | BS 2782 620A |
Melt Flow Rate | |||
150℃,21.6kg | 7.0 | g/10min | Internal Method |
MECHANICAL | Nominal value | Unit | Test method |
---|---|---|---|
tensile strength | 13.0 | MPa | IEC 60811-1-1 |
Tensile strain | |||
fracture | 170 | % | IEC 60811-1-1 |
Fracture, -30 ℃ | 50 | % | IEC 60811-1-4 |
Aging performance | Nominal value | Unit | Test method |
---|---|---|---|
The rate of change in tensile strength | |||
100℃,168 hr | 12 | % | IEC 60811-1-2 |
Changes in tensile stress during fracture | |||
100℃,168 hr | -12 | % | IEC 60811-1-2 |
THERMAL | Nominal value | Unit | Test method |
---|---|---|---|
deformation | |||
90℃ | 35 | % | IEC 60811-3-1 |
Low temperature bending | |||
-30℃ | pass | IEC 60811-1-4 | |
Temperature index | > 300 | ℃ | ISO 4589-3 |
Electrical performance | Nominal value | Unit | Test method |
---|---|---|---|
Insulation resistance constant – Ki | IEC 60502 | ||
20℃ | 7.7E+9 | ohms·cm | IEC 60502 |
90℃ | 5.7E+7 | ohms·cm | IEC 60502 |
FLAME CHARACTERISTICS | Nominal value | Unit | Test method |
---|---|---|---|
Extreme oxygen index | 41 | % | ISO 4589-2 |
Supplementary information | Nominal value | Unit | Test method |
---|---|---|---|
Halogen Acid Gas Evolution | < 0.50 | % | IEC 60754-1 |
tear strength | 6 | N/mm | BS 6469 |
Process Conditions | |||
---|---|---|---|
Extrusion | Nominal value | Unit | Test method |
Barrel 1 zone temperature | 120 | °C | |
Barrel 2 zone temperature | 130 | °C | |
Barrel 3 zone temperature | 140 | °C | |
Barrel 4 zone temperature | 150 | °C | |
Melt temperature | < 170 | °C | |
Head temperature | 160 | °C | |
Nozzle temperature | 160 | °C |
Notes |
---|
【 Disclaimer 】 Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials. |