Durethan® BKV 25 H2.0 LT 904040

About
Durethan®   BKV25H2.0LT 904040 (Dry) PA 6, 25 % glass fibers, injection molding, heat-aging stabilized, improved laser-transparency, NIR-laser transparent coloring (black)&&Durethan®   BKV25H2.0LT 904040 PA 6, 25 % glass fibers, injection molding, heat-aging stabilized, improved laser-transparency, NIR-laser transparent coloring (black)&&Durethan®   BKV25H2.0LT 904040 PA 6, 25 % glass fibers, injection molding, heat-aging stabilized, improved laser-transparency, NIR-laser transparent coloring (black)&&

Product Description
SupplierLANXESS
GenericPA6
Material StatusCommercial: Active
FeaturesGood heat aging resistance,Heat Stabilized,HB
AvailabilitysAfrica & Middle East ,North America,Latin America,Asia Pacific,Europe
Process MethodsInjection Molding

Technical Data
PHYSICALNominal valueUnitTest method
Density1.32g/cm³ISO 1183
Apparent density0.70g/cm³ISO 60
Shrinkage rate 
TD:280℃,3.0 mm0.88%ISO 2577
TD:120℃,3.0 mm,2 hrs0.14%ISO 294-4
MD:280℃,3.0 mm0.21%ISO 2577
MD:120℃,3.0 mm,2 hrs0.040%ISO 2577
Water absorption rate
Saturation, 23 ℃7.5%ISO 62
Equilibrium, 23 ℃, 50% RH2.2%ISO 62

filmNominal valueUnitTest method
Membrane puncture strength ISO 6603-2
2.60JISO 6603-2
3.40JISO 6603-2
Membrane puncture force ISO 6603-2
832NISO 6603-2
926NISO 6603-2

IMPACTNominal valueUnitTest method
Charpy Notched Impact Strength ISO 179/1eA
-40℃< 10kJ/m²ISO 179/1eA
-30℃< 10kJ/m²ISO 179/1eA
23℃< 10kJ/m²ISO 179/1eA
Charpy Unnotch Impact strength ISO 179/1eU
-30℃45kJ/m²ISO 179/1eU
23℃60kJ/m²ISO 179/1eU
Impact strength of cantilever beam notch ISO 180/1A
-40℃< 10kJ/m²ISO 180-1A
-30℃< 10kJ/m²ISO 180-1A
Notched impact strength of cantilever beam ISO 180/1U
-30℃60kJ/m²ISO 180/1U
23℃65kJ/m²ISO 180/1U

THERMALNominal valueUnitTest method
Hot deformation temperature
8.0 MPa, unannealed120ISO 75-2/C
1.8 MPa, unannealed200ISO 75-2/A
0.45 MPa, unannealed215ISO 75-2/B
Vicat Softening Temp
B120> 200ISO 306/B120
Melting temperature222ISO 11357-3
Linear coefficient of thermal expansion
TD:23~55℃9.0E-51/℃ISO 11359-2
MD:23~55℃3.0E-51/℃ISO 11359-2

Electrical performanceNominal valueUnitTest method
Surface resistivity1.0E+14ohmsIEC 60093
Volume resistivity
23℃1.0E+15ohms·cmIEC 60093
Dielectric strength
23 ℃,1 mm40kV/mmIEC 60243-1
Relative permittivity IEC 60250
23℃,100 Hz4.00 IEC 60250
23℃,1 MHz4.00 IEC 60250
Dissipation factor IEC 60250
23℃,100 Hz5.0E-3 IEC 60250
23℃,1 MHz0.015 IEC 60250
Compared to the leakage tracing index IEC 60112
Solution A400VIEC 60112
Solution B275VIEC 60112

FLAME CHARACTERISTICSNominal valueUnitTest method
Flame retardant level UL 94
1.60 mmHB UL 94
3.20 mmHB UL 94
Glowing wire flammability index
2.0 mm650IEC 60695-2-12
Extreme oxygen index23%ISO 4589-2
Flame retardant levelpassed ISO 3795

Supplementary informationNominal valueUnitTest method
ISO ShortnamePA 6, GHR, 14-080, GF25 ISO 1874

MECHANICALNominal valueUnitTest method
Tensile modulus
23℃8400MPaISO 527-1-2
tensile strength
Fracture, 23 ℃160MPaISO 527-2/5
Tensile strain
Fracture, 23 ℃3.0%ISO 527-2/5
Tensile Creep Modulus(1 hr)MPaISO 899-1
Tensile creep modulus
1000 hrMPaISO 899-1
Bending modulus
23℃7200MPaISO 178-A
bending strength 
3.50% strain230MPaISO 178-A
23℃250MPaISO 178
Bending strain5.0%
Ball hardness190MPaISO 2039-1

Process Conditions
injectionNominal valueUnitTest method
Drying Temperature – Dry Air Dryer80°C
Drying Time – Dry Air Dryer2.0 to 6.0hr
Processing (melt) temperature270 to 290°C
Mold temperature80 to 120°C
Residual Moisture Content0.030 to 0.12%

Notes
1. Typical properties: these are not to be construed as specifications.
2. 150x105x3mm, 4 hr
3. 150x105x3mm, 80°C MT, 500 bar
4. 0.079 in/min
5. 2 mm/min
6. 10°C/min
7. Procedure A
【 Disclaimer 】
Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials.