About |
---|
Prime Tuff-X FR is our Prime Tuff-X with a flame retardant characteristic. It has a higher flexural modulus than Prime Tuff-X and a flammability V1 in accordance with UL Standard 94. Applications: Tuff-X FR has very good chemical resistance, can be used in interior or exterior applications where UV protection is called for and has excellent stiffness and durability. Typical applications for this product include battery covers and side panels on lift trucks, tow motors and construction equipment. Processing: The same processing equipment, tooling and operating parameters used to for our Prime Tuff-X material may also be used for this product. Finishing: Prime Tuff-X FR can be fabricated and bonded using the same techniques that are used for our Prime Tuff-X. Please contact your Primex Plastics representative for more information on finishing, fabricating, or the thermoforming process. Colors, Textures and Capabilities: Prime Tuff-X FR can be color matched or even painted with a two part paint system. Tuff-X FR is available in gauges from .090 to .400 and up to 120″ wide. Textures include Calf Grain, FL/HC, H/C,Smooth, Levant ll and Diamond Plate.&& |
Product Description | |
---|---|
Generic | 3D打印材料 |
Material Status | Commercial: Active |
Features | Good Rigidity,Weather resistance is good,High impact resistance,Flame Characteristics,High Heat Resistance,Good Tensile Strength,Durability,Solvent resistance,low-temperature impact resistance,Agglomerability,V-1 |
Availabilitys | North America,Europe |
Technical Data | |||
---|---|---|---|
PHYSICAL | Nominal value | Unit | Test method |
Density | 1.18 | g/cm³ | ASTM D792 |
Melt Flow Rate | 1.0 | g/10min | ASTM D1238 |
MECHANICAL | Nominal value | Unit | Test method |
---|---|---|---|
tensile strength | |||
yield | 20.7 | MPa | ASTM D638 |
Tensile strain | ASTM D638 | ||
yield | 13 | % | ASTM D638 |
fracture | 230 | % | ASTM D638 |
Bending modulus | 2280 | MPa | ASTM D790 |
IMPACT | Nominal value | Unit | Test method |
---|---|---|---|
Drop hammer impact | ASTM D5420 | ||
-30℃ | 33.4 | J | ASTM D5420 |
23℃ | > 36.2 | J | ASTM D5420 |
FLAME CHARACTERISTICS | Nominal value | Unit | Test method |
---|---|---|---|
3.00 mm | V-1 | UL 94 |
Notes |
---|
1. Typical properties: these are not to be construed as specifications. |
2. >0.118 in |
【 Disclaimer 】 Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials. |