About |
---|
Product Description | |
---|---|
Generic | PS (GPPS) |
Material Status | Commercial: Active |
Technical Data | |||
---|---|---|---|
PHYSICAL | Nominal value | Unit | Test method |
Melt Volume Rate | |||
200℃,5kg | 3.2 | cm³/10min | ISO 1133 |
Density | 1.04 | g/cm³ | ISO 1183 |
Water absorption rate | <0.1 | % | ISO 62 |
MECHANICAL | Nominal value | Unit | Test method |
---|---|---|---|
Tensile stress | |||
yield | 53 | MPa | ISO 527 |
Tensile strain | |||
fracture | 3 | % | ISO 527 |
Tensile modulus | 3300 | MPa | ISO 527 |
Bending modulus | 102 | MPa | ISO 178 |
Rockwell hardness | |||
Level L | 100 | ASTM D785 |
IMPACT | Nominal value | Unit | Test method |
---|---|---|---|
Charpy Unnotch Impact strength | 17 | kJ/m² | ISO 179/1eU |
Charpy Notched Impact Strength | 3 | kJ/m² | ISO 179/1eA |
Notched impact strength of cantilever beam | 11 | KJ/m² | ISO 180 |
THERMAL | Nominal value | Unit | Test method |
---|---|---|---|
Vicat Softening Temp | |||
B/503 ,50N,50℃/h | 101 | ℃ | ISO 306 |
Hot deformation temperature | |||
0.45 MPa | 96 | ℃ | ISO 75 |
FLAME CHARACTERISTICS | Nominal value | Unit | Test method |
---|---|---|---|
Flame retardant level | HB | UL 94 |
Electrical performance | Nominal value | Unit | Test method |
---|---|---|---|
Volume resistivity | >1014 | ohms·cm | IEC 60093 |
Process Conditions | |||
---|---|---|---|
Extrusion molding | Nominal value | Unit | Test method |
injection molding | Nominal value | Unit | Test method |
Melt Temperature | 200-240 | ℃ | |
Shrinkage rate | 0.3-0.6 | % | |
Melt Temperature | 180-250 | ℃ | |
Mold temperature | 10-60 | ℃ |
Notes |
---|
【 Disclaimer 】 Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials. |