| About |
|---|
| A silane grafted crosslinkable polyethylene compound, curable by exposure to moisture, for insulation of power cables and possessing excellent extrudability at high out put rate. PP 408 is based on a high molecular weight polymer and has melt index in the range of 0.5 to 0.8. It has especially developed for low voltage cable insulation and for sheathing purpose. DESCRIPTION : This compound utilizes the system for cross – linking of polyethylene developed by DOW Corning and known as Sioplas. It is a two component system comprising a silylated ethylene polymer known as the graft copolymer PP 408 , and a master batch PP 401 containing a cross – linking catalyst. The two materials normally used in the ratio of 95 parts graft to 5 parts catalyst master batch.&& |
| Product Description | |
|---|---|
| Generic | XLPE |
| Material Status | Commercial: Active |
| Features | Crosslinked,High molecular weight |
| Availabilitys | Africa & Middle East |
| Process Methods | Extrusion |
| Technical Data | |||
|---|---|---|---|
| PHYSICAL | Nominal value | Unit | Test method |
| Density | 0.925 | g/cm³ | ASTM D1505 |
| Melt Flow Rate | |||
| 190℃,2.16kg | 0.50 | g/10min | ASTM D1238 |
| MECHANICAL | Nominal value | Unit | Test method |
|---|---|---|---|
| tensile strength | |||
| fracture | 18.0 | MPa | IEC 60811 |
| Tensile strain | |||
| fracture | 550 | % | IEC 60811 |
| Aging performance | Nominal value | Unit | Test method |
|---|---|---|---|
| The rate of change in tensile strength in air | |||
| 135℃,168 hr | 10 | % | IEC 60811 |
| Changes in tensile stress during fracture in air | |||
| 135℃,168 hr | 15 | % | IEC 60811 |
| THERMAL | Nominal value | Unit | Test method |
|---|---|---|---|
| thermosetting | IEC 60811 | ||
| Elongation under load: 200 ℃ | 100 | % | IEC 60811 |
| Maximum permanent elongation after cooling: 200 ℃ | 5.0 | % | IEC 60811 |
| Electrical performance | Nominal value | Unit | Test method |
|---|---|---|---|
| Volume resistivity | |||
| 20 ℃ | 2.4E+16 | ohms·cm | IEC 60502 |
| Dielectric strength | 25 | kV/mm | IEC 60243-1 |
| Dielectric constant | 2.30 | IEC 60250 | |
| power factor | |||
| 23℃ | 4.00E-4 | IEC 250 |
| Process Conditions | |||
|---|---|---|---|
| Extrusion | Nominal value | Unit | Test method |
| Barrel 1 zone temperature | 160 | °C | |
| Barrel 2 zone temperature | 170 | °C | |
| Barrel 3 zone temperature | 180 | °C | |
| Barrel 4 zone temperature | 190 | °C | |
| Barrel 5 zone temperature | 200 | °C | |
| Nozzle temperature | 210 | °C | |
| Notes |
|---|
| 1. Typical properties: these are not to be construed as specifications. |
| 2. 15 min, 0.2 N/mm² |
| 3. 50 Hz |
| 【 Disclaimer 】 Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials. |