LEXAN™ HPB3144G resin

About
标准流动性、透明、高纯度聚碳酸酯共聚物树脂,氧渗透率降低,水汽传质率降低。用于医疗设备和药物应用。卫生保健管理的改变,生物兼容(iso10993或USP类VI),符合食品接触级。

Product Description
SupplierSABIC
GenericPolycarbonate
Material StatusCommercial: Active
FeaturesFood contact compliance
AvailabilitysNorth America

Technical Data
MECHANICALNominal valueUnitTest method
Rockwell hardness
Level L108ASTM D785
M-level93ASTM D785
Taber wear and tear
CS-17,1kg10
mg/1000cyASTM D 1044
mg/1000cySABIC Method
tensile strength
Yield, 50 mm/min80MPaISO 527
Fracture, 50 mm/min60MPaISO 527
Tensile strain
Yield, 50 mm/min7%ISO 527
Fracture, 50 mm/min40%ISO 527
Tensile modulus
1 mm/min2450MPaISO 527
bending strength
Yield, 2 mm/min108MPaISO 178
Bending modulus
2 mm/mim2450MPaISO 178
Ball hardness
H358/30128MPaISO 2039-1
Pencil hardness test
1kgfHASTM D 3363
Erikson scratch depth
6N14micrometerSABIC Metho

IMPACTNominal valueUnitTest method
Impact strength of cantilever beam notch
23℃30J/mASTM D256
-30℃30J/mASTM D256
Total energy of instrument impact
23℃305cm-kgfASTM D 3763
Notched impact strength of cantilever beam
23℃NBJ/mASTM D 4812
23℃,80*10*3NBkJ/m²ISO 180/1U
-30℃,80*10*345kJ/m²ISO 180/1U
23℃,80*10*4NBkJ/m²ISO 180/1U
-30℃,80*10*447kJ/m²ISO 180/1U
Impact strength of cantilever beam notch
23℃,80*10*350kJ/m²ISO 180-1A
-30℃,80*10*340kJ/m²ISO 180-1A
80*10*4 -30℃30kJ/m²ISO 180-1A
80*10*3 sp=62mm,23℃30kJ/m²ISO 179/1eA
80*10*3 sp=62mm,-30℃30kJ/m²ISO 179/1eA
80*10*4 sp=62mm,23℃30kJ/m²ISO 179/1eA
80*10*4 sp=62mm,-30℃NBkJ/m²ISO 179/1eA
Charpy Notched Impact Strength
80 * 10 * 3, 62mm span
23 ℃, 80 * 10 * 3, 62mm spanNBkJ/m²ISO 179/1eU
-30 ℃, 80 * 10 * 3, 62mm span47kJ/m²ISO 179/1eU
23 ℃, 80 * 10 * 4, 62mm spanNBkJ/m²ISO 179/1eU
-30 ℃, 80 * 10 * 4, 62mm span47kJ/m²ISO 179/1eU

THERMALNominal valueUnitTest method
Vicat Softening Temp139ASTM D1525
Hot deformation temperature
0.45 MPa, 100 mm span131ISO 75/Be
1.8 MPa, 100 mm span118ISO 75/Ae
Unannealed, 6.4 mm
Unannealed, 3.2 mm
0.45 MPa133ASTM D 648
1.8MPa119ASTM D 648
0.45 MPa133ASTM D 648
1.8MPa119ASTM D 648
Linear expansion coefficient, -40 ℃ to 40 ℃
flow7.E-051/℃ASTM E 831
transverse7.E-051/℃ASTM E 831
specific heat1.4J/g-℃ASTM C 351
Thermal conductivity coefficient
0.2W/m/℃ASTM C177
0.2W/m/℃ISO 8302
Linear expansion coefficient, from 23 ℃ to 80 ℃
flow7.E-051/℃ISO 11359-2
transverse7.E-051/℃ISO 11359-2
Ball pressure test
125℃±2℃PASSESIEC 60695-10-2
Maximum approximation value140IEC 60695-10-2
Vicat Softening Temp
B50138ISO 306
B120140ISO 306

PHYSICALNominal valueUnitTest method
Density1.2ASTM D792
Specific volume0.85cm³/gASTM D 792
Water absorption rate
24hr,50% RH0.04%ASTM D570
Saturation, 23 ℃0.27%ISO 62
23℃,50% RH0.13%ISO 62
24hr0.08%ASTM D570
Equilibrium, 23 ℃0.28%ASTM D570
Equilibrium, 100 ℃0.13%ASTM D570
Shrinkage rate
MD:3.2 mm0.5 – 0.8%Internal Method
Melt Flow Rate
300℃,1.20kg14.5g/10minASTM D1238
Density1.17ISO 1183
Melt Volume Rate
300℃,2.16 kg13cm³/10minISO 1133

optical performanceNominal valueUnitTest method
Transmittance
2.54 mm88%ASTM D1003
Haze
2.54 mm<0.8%ASTM D1003
Refractive index1.586ASTM D542
Refractive index1.586ISO 489

Electrical performanceNominal valueUnitTest method
Volume resistivity>1.E+17ohms·cmASTM D257
Relative permittivity
50-60 Hz2.9ASTM D150
1 MHz2.8ASTM D150
Compared to the leakage tracing index2PLC CodeUL 746A

Process Conditions
injection moldingNominal valueUnitTest method
Drying temperature120°C
Drying time3 – 4hrs
Maximum water content0.02%
Melt temperature295 – 315°C
Nozzle temperature290 – 310°C
Front Section Zone 3 Temperature295 – 315°C
Temperature in Zone 2 of the middle section280 – 305°C
Temperature in Zone 1 of the rear section260 – 280°C
Mold temperature80 – 115°C
Hopper temperature70 – 95°C

Notes
【 Disclaimer 】
Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials.