FLEX NORYL™ Resin WCD883AU

About
Flexible and non-halogenated flame retardant extrusion grade intended for evaluation in applications such as jacket of HD 21.14 flexible cables. Flame retardant performance capable of meeting EN 50265-2-1 requirement.&&

Product Description
SupplierSABIC
GenericPPO(PPE)+TPE
Material StatusCommercial: Active
FeaturesGood flexibility,Halogen free,Flame Characteristics
AvailabilitysAsia Pacific

Technical Data
PHYSICALNominal valueUnitTest method
Density1.17g/cm³ASTM D792
Melt Flow Rate
250℃,10.0kg4.0g/10minASTM D1238
Water absorption rate
23℃,24hr0.020%ISO 62

THERMALNominal valueUnitTest method
Heat Deformation(100℃)23%UL 1581

Electrical performanceNominal valueUnitTest method
Surface resistivity2.5E+16ohmsASTM D257
Volume resistivity5.6E+15ohms·cmASTM D257
Dielectric strength
2 mm in oil25kV/mmASTM D149
Dielectric constant
1.00 GHz3.00 ASTM D150
Dissipation factor
1 GHz3.0E-3 ASTM D150
Compared to the leakage tracing index600VIEC 60112

FLAME CHARACTERISTICSNominal valueUnitTest method
Glowing wire flammability index
3.0 mm850IEC 60695-2-12
Igniting temperature of the hot wire
3 mm775IEC 60695-2-13
Extreme oxygen index36%ISO 4589-2
Vertical Flame TestPASSES EN 50265-2-1
Smoke density
Flaming,Ds max:500.0 µm57 
Non-Flaming,Ds max:500.0 µm140 

MECHANICALNominal valueUnitTest method
Shore hardness
Shore A, 30 seconds< 87 ASTM D2240
tensile strength
fracture18.0MPaUL 1581
fracture14.0MPaASTM D638
Fracture, 136 ℃19.0MPaUL 1581
fracture15.0MPaISO 527-2/50
Tensile strain
fracture260%UL 1581
fracture260%ASTM D638
Fracture, 136 ℃240%UL 1581
fracture240%ISO 527-2/50
Bending modulus
100 mm span30.0MPaASTM D790
40.0MPaISO 178

Process Conditions
Squeeze descriptionNominal valueUnitTest method

Notes
1. Typical properties: these are not to be construed as specifications.
2. 2.0 mm wire with 0.12 mm x 20 stranded copper
3. Type I, 2.0 in/min
4. After 7 days. Tested on 2.0 mm wire with 0.12 mm x 20 stranded copper
5. 6 days, 2.0 mm wire with 0.12 mm x 20 stranded copper
6. 0.49 in/min
7. 250g, 2.0 mm wire with 0.12 mm x 20 stranded copper
8. Plaque
9. UL 1581 tested on 2.0 mm wire with 0.12 mm x 20 stranded copper
【 Disclaimer 】
Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials.