| About |
|---|
| SD POLYCA CF5000 series are carbon fiber reinforced grades. These grades give very high flexural strength and flexural modulus, and suitable for housing of electronic products. |
| Product Description | |
|---|---|
| Supplier | Sumitomo |
| Generic | Polycarbonate |
| Material Status | Commercial: Active |
| Availabilitys | Asia Pacific |
| Technical Data | |||
|---|---|---|---|
| PHYSICAL | Nominal value | Unit | Test method |
| Density | 1.23 | g/cm³ | ISO 1183 |
| Shrinkage rate | |||
| MD | 0.10 to 0.30 | % | |
| TD | 0.30 to 0.50 | % | |
| Water absorption rate | |||
| 23℃,24hr | 0.15 | % | ASTM D570 |
| IMPACT | Nominal value | Unit | Test method |
|---|---|---|---|
| Charpy Notched Impact Strength | |||
| 23℃ | 7.0 | kJ/m² | ISO 179 |
| Impact strength of cantilever beam notch | |||
| 23℃ | 78 | J/m | ASTM D256 |
| THERMAL | Nominal value | Unit | Test method |
|---|---|---|---|
| Hot deformation temperature | |||
| 0.45 MPa, unannealed | 146 | ℃ | ASTM D648 |
| 1.8 MPa, unannealed | 142 | ℃ | ASTM D648 |
| Linear coefficient of thermal expansion | |||
| MD | 2.0E-5 | 1/℃ | |
| TD | 6.0E-5 | 1/℃ |
| Electrical performance | Nominal value | Unit | Test method |
|---|---|---|---|
| Volume resistivity | 1.0E+3 | ohms·cm | IEC 60093 |
| MECHANICAL | Nominal value | Unit | Test method |
|---|---|---|---|
| Rockwell hardness | |||
| R-level | 123 | ASTM D785 | |
| Tensile modulus | 7500 | MPa | ISO 527-2 |
| tensile strength | 108 | MPa | ASTM D638 |
| Tensile strain | |||
| fracture | 4.0 | % | ASTM D638 |
| Bending modulus | |||
| — | 6080 | MPa | ASTM D790 |
| — | 7000 | MPa | ISO 178 |
| bending strength | 167 | MPa | ASTM D790 |
| Notes |
|---|
| 【 Disclaimer 】 Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials. |