Vectra® V400P

About
Co-extrudable LCP for Barrier Applications. Vectra V400P Liquid Crystal Polymer is characterized by its excellent barrier properties independent of relative humidity, chemical resistance and contact clarity in thin film applications. This material is not suitable for medical or dental implants. Chemical abbreviation according to ISO 1043-1 : LCP Inherently flame retardant&&

Product Description
SupplierCelanese
Generic液态聚合物
Material StatusCommercial: Active
FeaturesGood Clarity,Halogen free,Flame Characteristics,Block resin,Solvent resistance
AvailabilitysNorth America,Europe

Technical Data
PHYSICALNominal valueUnitTest method
Density1.40g/cm³ISO 1183
Melt Flow Rate
230℃,2.16kg14g/10minInternal Method
Water absorption rate
Equilibrium, 23 ℃, 50% RH0.040%ISO 62

MECHANICALNominal valueUnitTest method
Tensile modulus14400MPaISO 527-2/1A/1
tensile strength
fracture151MPaISO 527-2/1A/5
Tensile strain
fracture1.6%ISO 527-2/1A/5

filmNominal valueUnitTest method
Oxygen permeability DIN 53380-3
23℃1.3cc-25µm/m²-day-atmDIN 53380-3
23℃1.4cc-25µm/m²-day-atmDIN 53380-3
water vapor permeability
38℃0.400g-25µm/(m² day-atm)DIN 53122

THERMALNominal valueUnitTest method
Hot deformation temperature
1.8 MPa, unannealed111ISO 75-2/A
Glass transition temperature110ISO 3146

Process Conditions
injectionNominal valueUnitTest method
Drying temperature90°C
Drying time8.0 to 24hr
Recommended maximum moisture content0.010%
Barrel rear temperature185 to 195°C
Barrel middle temperature205 to 215°C
Barrel front temperature205 to 215°C
Nozzle temperature200 to 210°C
Processing (melt) temperature225 to 235°C

Notes
1. Typical properties: these are not to be construed as specifications.
2. 100% RH
3. 0% RH
4. Onset
【 Disclaimer 】
Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials.