About |
---|
Polypropylene copolymer medium flow, flame rating UL94 HB.&& |
Product Description | |
---|---|
Generic | PP copolymer |
Material Status | Commercial: Active |
Features | Moderate liquidity,Copolymer |
Availabilitys | Europe |
Process Methods | Injection Molding |
Technical Data | |||
---|---|---|---|
PHYSICAL | Nominal value | Unit | Test method |
Density | 0.91 | g/cm³ | ISO 1183 |
Water absorption rate | |||
23℃,24hr | 0.02 | % | ISO 62 |
Melt Flow Rate | |||
230℃,2.16kg | 10 | g/10min | ISO 1133 |
MECHANICAL | Nominal value | Unit | Test method |
---|---|---|---|
tensile strength | |||
23℃ | 22 | MPa | ISO 527-2 |
Tensile strain | |||
Fracture, 23 ℃ | 80 | % | ISO 527-2 |
Bending modulus | |||
23℃ | 1100 | MPa | ISO 178 |
THERMAL | Nominal value | Unit | Test method |
---|---|---|---|
Hot deformation temperature | |||
1.8 MPa, unannealed | 55 | ℃ | ISO 75-2/Af |
0.45 MPa, unannealed | 115 | ℃ | ISO 75-2/Bf |
Vicat Softening Temp | |||
B50 | 75 | ℃ | ISO 306 |
Electrical performance | Nominal value | Unit | Test method |
---|---|---|---|
Compared to the leakage tracing index | 600 | V | IEC 60112 |
FLAME CHARACTERISTICS | Nominal value | Unit | Test method |
---|---|---|---|
All color | 1.60mm | HB | UL-94 |
Process Conditions | |||
---|---|---|---|
injection | Nominal value | Unit | Test method |
Drying temperature | 60-90 | °C | |
Drying time | 2.0-6.0 | Hr | |
Recommended moisture content | <=0.20 | % | |
Barrel rear temperature | 200-260 | °C | |
Barrel middle temperature | 210-270 | °C | |
Barrel front temperature | 220-280 | °C | |
Nozzle temperature | 230-290 | °C | |
Mold temperature | 20-90 | °C |
Notes |
---|
1. Typical properties: these are not to be construed as specifications. |
2. 0.039 in/min |
【 Disclaimer 】 Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials. |