About |
---|
Stainless Steel Fiber – EMI/RFI Shielding&& |
Product Description | |
---|---|
Generic | PPSU |
Material Status | Commercial: Negative |
Features | EMI,RFI |
Availabilitys | Africa & Middle East ,North America,Latin America,Asia Pacific,Europe |
Process Methods | Injection Molding |
Technical Data | |||
---|---|---|---|
PHYSICAL | Nominal value | Unit | Test method |
Density | 1.41 | g/cm³ | ASTM D792 |
Shrinkage rate | |||
MD:3.2 mm | 0.40 to 0.90 | % | ASTM D955 |
water content | 0.040 | % |
MECHANICAL | Nominal value | Unit | Test method |
---|---|---|---|
Tensile modulus | 2340 | MPa | ASTM D638 |
tensile strength | 68.9 | MPa | ASTM D638 |
Tensile strain | |||
yield | > 10 | % | ASTM D638 |
Bending modulus | 2410 | MPa | ASTM D790 |
bending strength | 89.6 | MPa | ASTM D790 |
IMPACT | Nominal value | Unit | Test method |
---|---|---|---|
Impact strength of cantilever beam notch | |||
3.2mm | 530 | J/m | ASTM D256 |
Notched impact strength of cantilever beam | |||
3.2 mm | 无断裂 | ASTM D4812 |
Electrical performance | Nominal value | Unit | Test method |
---|---|---|---|
Surface resistivity | |||
— | < 1.0E+3 | ohms | ESD STM11.11 |
— | < 1.0E+4 | ohms | ASTM D257 |
Volume resistivity | < 1.0E+2 | ohms·cm | ASTM D257 |
Electrostatic attenuation | < 2.0 | sec | FTMS 101C 4046.1 |
Supplementary information | Nominal value | Unit | Test method |
---|---|---|---|
Primary Additive | 10 | % |
Process Conditions | |||
---|---|---|---|
injection | Nominal value | Unit | Test method |
Drying temperature | 149 | °C | |
Drying time | 6.0 | hr | |
Dew Point | -32 | °C | |
Processing (melt) temperature | 343 to 377 | °C | |
Mold temperature | 135 to 177 | °C | |
Injection pressure | 68.9 to 103 | MPa |
Notes |
---|
【 Disclaimer 】 Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials. |