NORYL™ WCD895 resin

About
Non-halogenated flame retardant Flexible NORYL extrusion grade intended for evaluation in wire cable jacket. Excellent flame retardant performance with robust tensile strength, tensile elongation, heat deformation, capable of VW-1 performance and 80C temperature rating as defined by UL 1581. Processing typically conducted on standard extrusion equipment. UL 1581 tests conducted on 2.0mm wire with 0.12mm X 20 stranded copper conductor.&&

Product Description
SupplierSABIC
GenericPPO(PPE)+TPE
Material StatusCommercial: Active
FeaturesGood flexibility,Halogen free,Flame Characteristics
AvailabilitysAsia Pacific

Technical Data
PHYSICALNominal valueUnitTest method
Density1.03g/cm³ASTM D792
Melt Flow Rate
250℃,10.0kg17g/10minASTM D1238

THERMALNominal valueUnitTest method
UL temperature rating80UL 1581
Heat Deformation(100℃)4.0%UL 1581

Electrical performanceNominal valueUnitTest method
Volume resistivity4.7E+15ohms·cmIEC 60093
Compared to the leakage tracing index600VIEC 60112

FLAME CHARACTERISTICSNominal valueUnitTest method
Glowing wire flammability index
3.0 mm960IEC 60695-2-12
Igniting temperature of the hot wire
3 mm775IEC 60695-2-13
VW-1PassUL 1581

MECHANICALNominal valueUnitTest method
Shore hardness
Shore A, 30 seconds89ASTM D2240
tensile strength
fracture27.0MPaUL 1581
fracture18.0MPaASTM D638
Fracture, 136 ℃27.0MPaUL 1581
fracture18.0MPaISO 527-2/50
Tensile strain
fracture240%UL 1581
fracture180%ASTM D638
Fracture, 113 ℃200%UL 1581
fracture210%ISO 527-2/50
Bending modulus
100 mm span80.0MPaASTM D790
70.0MPaISO 178

Process Conditions
ExtrusionNominal valueUnitTest method
Drying temperature75.0 to 85.0°C
Drying time5.0 to 7.0hr
Recommended maximum moisture content0.020%
Barrel 1 zone temperature180 to 220°C
Barrel 3 zone temperature220 to 250°C
Barrel 5 zone temperature220 to 250°C
Melt temperature220 to 250°C
Nozzle temperature220 to 250°C

Notes
1. Typical properties: these are not to be construed as specifications.
2. 2.0 mm wire with 0.12 mm x 20 stranded copper
3. Type I, 2.0 in/min
4. After 7 days. Tested on 2.0 mm wire with 0.12 mm x 20 stranded copper
5. 6 days, 2.0 mm wire with 0.12 mm x 20 stranded copper
6. 0.49 in/min
7. 2.0mm wire with 0.12 mm x 20 stranded copper
8. 250g, 2.0 mm wire with 0.12 mm x 20 stranded copper
【 Disclaimer 】
Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials.