Kingfa IC-701

About
Kingfa IC-701是一种丙烯腈丁二烯苯乙烯 + 尼龙(ABS+尼龙)材料,。 该产品在北美洲或亚太地区有供货,加工方式为:注射成型。 Kingfa IC-701的主要特性有: 阻燃/额定火焰 Good ESCR (Stress Crack Resistant) 低光泽度 高流动性 耐冲击 典型应用领域包括: 电气/电子应用 汽车行业 体育用品

Product Description
SupplierKingfa
GenericABS+PA
Material StatusCommercial: Active
FeaturesHigh impact resistance,High liquidity,Solvent resistance,High ESCR,Low Gloss
AvailabilitysNorth America,Asia Pacific
Process MethodsInjection Molding

Technical Data
PHYSICALNominal valueUnitTest method
Density1.10g/cm³ISO 1183
Melt Flow Rate
260℃,5.0kg25g/10minISO 1133
Shrinkage rate
23℃0.50 to 0.90%ISO 2577

IMPACTNominal valueUnitTest method
Impact strength of cantilever beam notch
23℃25kJ/m²ISO 180

THERMALNominal valueUnitTest method
Hot deformation temperature
0.45 MPa, unannealed86.0ISO 75-2/B
Vicat Softening Temp
B5095.0ISO 306

Electrical performanceNominal valueUnitTest method
Volume resistivity1.0E+13ohms·cmIEC 60093
Dielectric strength
2 mm in oil15kV/mmIEC 60243-1

FLAME CHARACTERISTICSNominal valueUnitTest method
Flame retardant level
1.50 mmHB 
3.00 mmHB 

MECHANICALNominal valueUnitTest method
Rockwell hardness
R-level95 ISO 2039-2
tensile strength48.0MPaISO 527-2/50
Tensile strain
fracture20%ISO 527-2/50
Bending modulus1900MPaISO 178
bending strength60.0MPaISO 178

Process Conditions
injectionNominal valueUnitTest method
Drying temperature80 to 90°C
Drying time4.0 to 6.0hr
Barrel rear temperature200 to 220°C
Barrel middle temperature220 to 240°C
Barrel front temperature230 to 250°C
Processing (melt) temperature230 to 250°C
Mold temperature70 to 90°C
Back pressure0.700 to 1.00MPa

Notes
【 Disclaimer 】
Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials.