Ultramid® 8202 HS

About
Ultramid 8202 HS is a heat stabilized, low viscosity, general purpose PA6 injection molding. It possesses the combination of strength and toughness and has excellent chemical and abrasion resistance. The heat stabilizer system extends the retention of properties at the more elevated temperatures. Excellent in filling thin walls or areas. Applications Ultramid 8202 HS is generally recommended for drapery hardware, gears, fittings, furniture casters, bearings, handles, clips, fasteners and thin parts.&&

Product Description
SupplierBASF
GenericPA6
Material StatusCommercial: Active
FeaturesGood Rigidity,Good flexibility,Low Viscosity,Good wear resistance,Solvent resistance,Heat Stabilized,Homopolymer,V-2
AvailabilitysNorth America,Asia Pacific
Process MethodsInjection Molding

Technical Data
PHYSICALNominal valueUnitTest method
Density1.13g/cm³ASTM D792
Density1.13g/cm³ISO 1183
Shrinkage rate
MD:3.2 mm1.2%
Water absorption rate
Saturation, 23 ℃9.5%ISO 62
saturated9.5%ASTM D570
Equilibrium, 23 ℃, 50% RH2.7%ISO 62
Balance, 50% RH2.7%ASTM D570
24hr1.6%ASTM D570
23℃,24hr1.6%ISO 62

IMPACTNominal valueUnitTest method
Charpy Notched Impact Strength
23℃3.5kJ/m²ISO 179
Charpy Unnotch Impact strength ISO 179
-30℃51kJ/m²ISO 179
23℃No Break ISO 179
Impact strength of cantilever beam notch ASTM D256
-40℃48J/mASTM D256
23℃58J/mASTM D256
Falling impact resistance
23℃142JInternal Method

THERMALNominal valueUnitTest method
Hot deformation temperature
1.8 MPa, unannealed65.0ASTM D648
1.8 MPa, unannealed60.0ISO 75-2/A
0.45 MPa, unannealed150ISO 75-2/B
0.45 MPa, unannealed178ASTM D648
Melting peak temperature220ASTM D3418
Melting temperature
DSC220ISO 3146
Linear coefficient of thermal expansion
MD8.3E-51/℃ASTM E831
0.71 mm130UL 746
1.5 mm130UL 746
3.0 mm130UL 746
6.0 mm130UL 746
Relative temperature index
Electrical performance UL 746
Strength mechanical performance UL 746
Impact mechanical performance UL 746
0.71 mm95.0UL 746
3.0 mm105UL 746
1.5 mm105UL 746
6.0 mm105UL 746

Electrical performanceNominal valueUnitTest method
Volume resistivity> 1.0E+13ohms·cmIEC 60093
1.50 mm> 1.0E+13ohms·cmASTM D257
Dielectric strength37kV/mmIEC 60243-1
1.5 mm22kV/mmASTM D149
Compared to the leakage tracing index600VIEC 60112

FLAME CHARACTERISTICSNominal valueUnitTest method
Flame retardant level UL 94
0.71 mmV-2 UL 94
1.50 mmV-2 UL 94
3.00 mmV-2 UL 94
6.00 mmV-2 UL 94

MECHANICALNominal valueUnitTest method
Tensile modulus ISO 527-2
23℃2700MPaISO 527-2
80℃485MPaISO 527-2
120℃360MPaISO 527-2
150℃290MPaISO 527-2
tensile strength ASTM D638
Yield, -40 ℃126MPaASTM D638
Yield, 23 ℃79.0MPaASTM D638
Yield, 80 ℃35.0MPaASTM D638
Yield, 121 ℃25.0MPaASTM D638
tensile strength ISO 527-2
Fracture, 23 ℃75.0MPaASTM D638
Yield, -40 ℃126MPaISO 527-2
Yield, 23 ℃78.0MPaISO 527-2
Yield, 80 ℃35.0MPaISO 527-2
Yield, 120 ℃25.0MPaISO 527-2
Yield, 150 ℃20.0MPaISO 527-2
Tensile strain ASTM D638
Fracture, 23 ℃55%ASTM D638
Yield, 23 ℃4.0%ISO 527-2
Yield, 23 ℃4.0%ASTM D638
Yield, 80 ℃42%ASTM D638
Yield, 121 ℃36%ASTM D638
Nominal tensile fracture strain
23℃25%ISO 527-2
Bending modulus ASTM D790
23℃2400MPaISO 178
-40℃3010MPaASTM D790
23℃2830MPaASTM D790
65℃500MPaASTM D790
90℃350MPaASTM D790
121℃305MPaASTM D790
bending strength ASTM D790
23℃85.0MPaISO 178
-40℃170MPaASTM D790
23℃108MPaASTM D790
65℃30.0MPaASTM D790
90℃20.0MPaASTM D790
121℃17.0MPaASTM D790
Rockwell hardness
R-level119 ASTM D785

Process Conditions
injectionNominal valueUnitTest method
Drying temperature80°C
Drying time2.0 to 4.0hr
Recommended maximum moisture content0.15%
Processing (melt) temperature240 to 285°C
Mold temperature65 to 80°C
Injection pressure3.50 to 12.5MPa
Injection speedFast 

Notes
1. Typical properties: these are not to be construed as specifications.
2. Method A (Short-Time)
【 Disclaimer 】
Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials.