SCHULADUR® A1 GF 30

About
30% glass fibre reinforced PBT/PET-blend&&

Product Description
SupplierA. Schulman
GenericPBT+PET
Material StatusCommercial: Negative
FeaturesHB
AvailabilitysEurope
Process MethodsInjection Molding

Technical Data
PHYSICALNominal valueUnitTest method
Density1.55g/cm³ISO 1183/A
Melt Volume Rate
260℃,2.16 kg20.0cm³/10minISO 1133
Water absorption rate
23℃,24hr0.30%ISO 62

IMPACTNominal valueUnitTest method
Charpy Notched Impact Strength ISO 179/1eA
-30℃8.0kJ/m²ISO 179/1eA
23℃8.0kJ/m²ISO 179/1eA
Charpy Unnotch Impact strength ISO 179/1eU
-30℃50kJ/m²ISO 179/1eU
23℃55kJ/m²ISO 179/1eU

THERMALNominal valueUnitTest method
Hot deformation temperature 
0.45 MPa, unannealed225ISO 75-2/Bf
1.8 MPa, unannealed205ISO 75-2/Af
Vicat Softening Temp 
A50218ISO 306/A50
B50204ISO 306
Ball pressure test
200℃通过 IEC 60695-10-2

Electrical performanceNominal valueUnitTest method
Surface resistivity> 1.0E+16ohmsIEC 60093
Volume resistivity> 1.0E+12ohms·cmIEC 60093
Compared to the leakage tracing index300VIEC 60112

FLAME CHARACTERISTICSNominal valueUnitTest method
Burning rate
2.0 mm26mm/minISO 3795
Flammability level IEC 60695-11-10, -20
1.5 mmHB IEC 60695-11-10, -20
3.0 mmHB IEC 60695-11-10, -20
Glowing wire flammability index IEC 60695-2-12
1.5 mm700IEC 60695-2-12
3.0 mm800IEC 60695-2-12
Igniting temperature of the hot wire IEC 60695-2-13
1.5 mm725IEC 60695-2-13
3 mm825IEC 60695-2-13
Extreme oxygen index19%ISO 4589-2

MECHANICALNominal valueUnitTest method
Ball hardness
H358/30263MPaISO 2039-1
Tensile modulus11000MPaISO 527-2/1A/1
tensile strength
fracture142MPaISO 527-2/1A/5
Tensile strain
fracture2.1%ISO 527-2/1A/5

Notes
1. Typical properties: these are not to be construed as specifications.
【 Disclaimer 】
Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials.