About |
---|
EVICOM™ VN225/3 is a Flexible Polyvinyl Chloride material. It is available in Europe for extrusion. Primary attribute of EVICOM™ VN225/3: RoHS Compliant. Typical application of EVICOM™ VN225/3: Wire & Cable&& |
Product Description | |
---|---|
Supplier | INEOS |
Generic | PVC, not specified |
Material Status | Commercial: Active |
Availabilitys | Europe |
Process Methods | Extrusion |
Technical Data | |||
---|---|---|---|
PHYSICAL | Nominal value | Unit | Test method |
Density | 1.37 | g/cm³ | BS 2782 |
THERMAL | Nominal value | Unit | Test method |
---|---|---|---|
Low temperature flexibility | < -40 | ℃ | BS 2782 |
Low temperature flexibility | -29 | ℃ | BS 2782 |
Electrical performance | Nominal value | Unit | Test method |
---|---|---|---|
Volume resistivity | |||
23℃ | 9.6E+12 | ohms·cm | BS 2782 |
Dielectric strength | |||
1.27 mm | 13 | kV/mm | BS 2782 |
FLAME CHARACTERISTICS | Nominal value | Unit | Test method |
---|---|---|---|
Extreme oxygen index | 22 | % | ISO 4589-2 |
MECHANICAL | Nominal value | Unit | Test method |
---|---|---|---|
Shore hardness | |||
Shore A, 15 seconds, 23 ℃ | 74 | BS 2782 | |
tensile strength | 13.4 | MPa | IEC 811-1-1 |
Tensile strain | |||
fracture | 310 | % | IEC 811-1-1 |
BS Softness(BSS°) | 48 | BS 2782 |
Process Conditions | |||
---|---|---|---|
Extrusion | Nominal value | Unit | Test method |
Barrel 1 zone temperature | 150 | °C | |
Barrel 2 zone temperature | 150 | °C | |
Barrel 3 zone temperature | 150 | °C | |
Barrel 4 zone temperature | 150 | °C | |
Connector temperature | 160 | °C | |
Nozzle temperature | 160 | °C |
Notes |
---|
1. TM2 , 6 & 8 |
2. Typical properties: these are not to be construed as specifications. |
3. Natural |
4. 20 in/min |
【 Disclaimer 】 Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials. |