About |
---|
Durethan® DP 2131/20 H2.0 900051 (干燥 ) PA 6, 20 % glass fibers, injection molding, heat-aging stabilized, improved surface finish, improved resistance to weathering&&Durethan® DP 2131/20 H2.0 900051 PA 6, 20 % glass fibers, injection molding, heat-aging stabilized, improved surface finish, improved resistance to weathering&& |
Product Description | |
---|---|
Supplier | LANXESS |
Generic | PA6 |
Material Status | Commercial: Active |
Features | Weather resistance is good,Good surface appearance,Heat Stabilized,HB |
Availabilitys | Africa & Middle East ,North America,Latin America,Asia Pacific,Europe |
Process Methods | Injection Molding |
Technical Data | |||
---|---|---|---|
PHYSICAL | Nominal value | Unit | Test method |
Density | 1.28 | g/cm³ | ISO 1183 |
Apparent density | 0.70 | g/cm³ | ISO 60 |
Shrinkage rate | ISO 2577 | ||
TD:280℃,2.0 mm | 0.54 | % | ISO 2577 |
TD:120℃,2.0 mm,4 hrs | 0.19 | % | ISO 2577 |
MD:280℃,2.0 mm | 0.35 | % | ISO 2577 |
MD:120℃,2.0 mm,4 hrs | 0.12 | % | ISO 2577 |
MECHANICAL | Nominal value | Unit | Test method |
---|---|---|---|
Tensile modulus | |||
23℃ | 7600 | MPa | ISO 527-1-2 |
tensile strength | |||
Fracture, 23 ℃ | 150 | MPa | ISO 527-2/5 |
Tensile strain | |||
Fracture, 23 ℃ | 3.0 | % | ISO 527-2/5 |
Bending modulus | |||
23℃ | 6400 | MPa | ISO 178-A |
bending strength | ISO 178/A | ||
3.50% strain, 23 ℃ | 200 | MPa | ISO 178-A |
23℃ | 225 | MPa | ISO 178-A |
Bending strain | 4.5 | % | ISO 178/A |
IMPACT | Nominal value | Unit | Test method |
---|---|---|---|
Charpy Notched Impact Strength | ISO 179/1eA | ||
-30℃ | < 10 | kJ/m² | ISO 179/1eA |
23℃ | < 10 | kJ/m² | ISO 179/1eA |
Charpy Unnotch Impact strength | ISO 179/1eU | ||
-30℃ | 40 | kJ/m² | ISO 179/1eU |
23℃ | 45 | kJ/m² | ISO 179/1eU |
Impact strength of cantilever beam notch | ISO 180/1A | ||
-30℃ | < 10 | kJ/m² | ISO 180-1A |
23℃ | < 10 | kJ/m² | ISO 180-1A |
Notched impact strength of cantilever beam | ISO 180/1U | ||
-30℃ | 35 | kJ/m² | ISO 180/1U |
23℃ | 35 | kJ/m² | ISO 180/1U |
Multi axial instrumented impact energy | ISO 6603-2 | ||
-30℃ | 4.00 | J | ISO 6603-2 |
23℃ | 5.00 | J | ISO 6603-2 |
THERMAL | Nominal value | Unit | Test method |
---|---|---|---|
Hot deformation temperature | |||
1.8 MPa, unannealed | 215 | ℃ | ISO 75-2/A |
0.45 MPa, unannealed | 213 | ℃ | ISO 75-2/B |
Vicat Softening Temp | |||
B120 | > 200 | ℃ | ISO 306/B120 |
Melting temperature | 222 | ℃ | ISO 11357-3 |
Linear coefficient of thermal expansion | |||
TD:23~55℃ | 8.9E-5 | 1/℃ | ISO 11359-2 |
MD:23~55℃ | 2.3E-5 | 1/℃ | ISO 11359-2 |
Electrical performance | Nominal value | Unit | Test method |
---|---|---|---|
Surface resistivity | 2.0E+15 | ohms | IEC 60093 |
Volume resistivity | |||
23℃ | 3.0E+15 | ohms·cm | IEC 60093 |
Relative permittivity | IEC 60250 | ||
23℃,100 Hz | 4.10 | IEC 60250 | |
23℃,1 MHz | 3.74 | IEC 60250 | |
Dissipation factor | IEC 60250 | ||
23℃,100 Hz | 8.0E-3 | IEC 60250 | |
23℃,1 MHz | 0.018 | IEC 60250 |
FLAME CHARACTERISTICS | Nominal value | Unit | Test method |
---|---|---|---|
Flame retardant level | UL 94 | ||
0.80 mm | HB | UL 94 | |
1.60 mm | HB | UL 94 |
Supplementary information | Nominal value | Unit | Test method |
---|---|---|---|
ISO Shortname | ISO 1874 PA 6, GHR, 14-080, GF20 | ISO 1874 |
Process Conditions | |||
---|---|---|---|
injection | Nominal value | Unit | Test method |
Drying Temperature – Dry Air Dryer | 80 | °C | |
Drying Time – Dry Air Dryer | 2.0 to 6.0 | hr | |
Processing (melt) temperature | 270 to 290 | °C | |
Mold temperature | 80 to 120 | °C | |
Residual Moisture Content | 0.030 to 0.12 | % |
Notes |
---|
【 Disclaimer 】 Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials. |