Extron® 200 GF HS

About
Extron 200 GF HS is a 20% glass fibre reinforced homopolymer polypropylene compound. It is a low flow injection moulding grade developed for rigid components requiring high heat deflection temperatures and low mould shrinkages. It is stabilized to meet automotive heat ageing requirements of 500hrs at 150°C.&&

Product Description
GenericPP homopolymerization
Material StatusCommercial: Active
FeaturesLow liquidity,Low contractility,Heat Stabilized,Homopolymer
AvailabilitysAsia Pacific
Process MethodsInjection Molding

Technical Data
PHYSICALNominal valueUnitTest method
Density1.05g/cm³ASTM D792
Melt Flow Rate
230℃,2.16kg2.0g/10minASTM D1238
Shrinkage rate
MD:3.0 mm0.20 to 0.80%ASTM D955

IMPACTNominal valueUnitTest method
Impact strength of cantilever beam notch
3mm53J/mASTM D256
Notched impact strength of cantilever beam
3 mm270J/mASTM D256

THERMALNominal valueUnitTest method
Hot deformation temperature
0.45 MPa, unannealed, 3.0 mm150
1.8 MPa, unannealed, 3.00 mm130
Linear coefficient of thermal expansion
MD:-30~30℃,3.00 mm4.0E-51/℃ASTM D696

MECHANICALNominal valueUnitTest method
Shore hardness
Shore D, 3.00 mm79 
Shore D, 15 seconds, 3.00 mm72 
Rockwell hardness
R-grade, 3.00 mm111 ASTM D785
tensile strength
3 mm59.0MPaASTM D638
Tensile strain
Fracture, 3 mm3.0%ASTM D638
Bending modulus
3 mm3900MPaASTM D790

Process Conditions
injectionNominal valueUnitTest method
Drying temperature100 to 120°C
Drying time2.0 to 4.0hr
Proposed maximum recycled material ratio10%
Processing (melt) temperature200 to 260°C
Mold temperature20 to 60°C
Injection speed中等 

Notes
1. Typical properties: these are not to be construed as specifications.
2. 2.0 in/min
【 Disclaimer 】
Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials.