About |
---|
Polyetherimide, Electro-Static Dissipative&& |
Product Description | |
---|---|
Generic | Polyetherimide |
Material Status | Commercial: Active |
Features | Conductive,Rapid Static Decay,V-0 |
Availabilitys | North America |
Technical Data | |||
---|---|---|---|
PHYSICAL | Nominal value | Unit | Test method |
Density | 1.31 | g/cm³ | ASTM D792 |
Water absorption rate | |||
23℃,24hr | 0.24 | % | ASTM D570 |
IMPACT | Nominal value | Unit | Test method |
---|---|---|---|
Impact strength of cantilever beam notch | |||
0.318mm | 53 | J/m | ASTM D256 |
THERMAL | Nominal value | Unit | Test method |
---|---|---|---|
Hot deformation temperature | |||
1.8 MPa, unannealed | 201 | ℃ | ASTM D648 |
Linear coefficient of thermal expansion | |||
MD | 5.0E-5 | 1/℃ | ASTM D696 |
Electrical performance | Nominal value | Unit | Test method |
---|---|---|---|
Surface resistivity | ESD S11.11 | ||
— | 1.0E+6 to 1.0E+9 | ohms | ESD S11.11 |
— | 1.0E+6 to 1.0E+8 | ohms | ESD S11.11 |
Volume resistivity | ESD S11.12 | ||
— | 1.0E+6 to 1.0E+9 | ohms·cm | ESD S11.12 |
— | 1.0E+6 to 1.0E+8 | ohms·cm | ESD S11.12 |
Electrostatic attenuation | 0.00200 | FTMS 101C 4046.1 |
FLAME CHARACTERISTICS | Nominal value | Unit | Test method |
---|---|---|---|
Flame retardant level | V-0 | UL 94 |
MECHANICAL | Nominal value | Unit | Test method |
---|---|---|---|
Rockwell hardness | |||
M-level | 109 | ASTM D785 | |
Tensile modulus | 3400 | MPa | ASTM D638 |
tensile strength | 110 | MPa | ASTM D638 |
Tensile strain | ASTM D638 | ||
yield | 7.0 | % | ASTM D638 |
fracture | 60 | % | ASTM D638 |
Bending modulus | 3400 | MPa | ASTM D790 |
bending strength | 103 | MPa | ASTM D790 |
Notes |
---|
1. Typical properties: these are not to be construed as specifications. |
2. 100 Volts |
3. 10 Volts |
【 Disclaimer 】 Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials. |