FLEX NORYL™ Resin WCD815U

About
Flexible, Ultra-violet stabilized and non-halogenated flame retardant extrusion grade intended for applications such as cable jacket in compliance with UL62. Flame retardant performance capable of meeting UL 1581 VW-1 requirement. 90C temperature rating as defined by UL 62 TPE category. Processing typically conducted on standard extrusion equipment. UL 1581 tests conducted on 2.0 mm wire with 0.12 mm x 20 stranded copper conductor.&&

Product Description
SupplierSABIC
GenericPPO(PPE)+TPE
Material StatusCommercial: Active
FeaturesWeather resistance is good,Good flexibility,Halogen free,Flame Characteristics
AvailabilitysAsia Pacific

Technical Data
PHYSICALNominal valueUnitTest method
Density1.03g/cm³ASTM D792
Melt Flow Rate
250℃,10.0kg10g/10minASTM D1238

THERMALNominal valueUnitTest method
Heat Deformation(121℃)10%UL 1581

Electrical performanceNominal valueUnitTest method
Surface resistivity1.6E+16ohmsASTM D257
Volume resistivity5.1E+15ohms·cmASTM D257
Dielectric strength
2 mm in oil25kV/mmASTM D149
Dielectric constant
5.00 GHz2.60 Internal Method
Dissipation factor
5 GHz2.0E-3 Internal Method
Compared to the leakage tracing index600VIEC 60112

FLAME CHARACTERISTICSNominal valueUnitTest method
Glowing wire flammability index
3.0 mm850IEC 60695-2-12
Igniting temperature of the hot wire
3 mm775IEC 60695-2-13
Extreme oxygen index27%ISO 4589-2
VW-1Pass UL 1581
Smoke density
Flaming,Ds max:500.0 µm120 
Non-Flaming,Ds max:500.0 µm170 

MECHANICALNominal valueUnitTest method
Shore hardness
Shore A, 30 seconds81 ASTM D2240
tensile strength
fracture22.0MPaUL 1581
fracture15.0MPaASTM D638
Fracture, 136 ℃23.0MPaUL 1581
fracture17.0MPaISO 527-2/50
Tensile strain
fracture330%UL 1581
fracture250%ASTM D638
Fracture, 136 ℃290%UL 1581
fracture260%ISO 527-2/50
Bending modulus
100 mm span20.0MPaASTM D790
20.0MPaISO 178

Process Conditions
Squeeze descriptionNominal valueUnitTest method

Notes
1. Typical properties: these are not to be construed as specifications.
2. 2.0 mm wire with 0.12 mm x 20 stranded copper
3. Type I, 2.0 in/min
4. After 7 days. Tested on 2.0 mm wire with 0.12 mm x 20 stranded copper
5. 6 days, 2.0 mm wire with 0.12 mm x 20 stranded copper
6. 0.49 in/min
7. 250g, 2.0 mm wire with 0.12 mm x 20 stranded copper
8. Plaque
【 Disclaimer 】
Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials.