Durethan® AKV 50 H2.0 901510

About
Durethan®   AKV 50 H2.0 901510 (干燥 ) PA 66, 50 % glass fibers, injection molding, heat-aging stabilized&&Durethan®   AKV 50 H2.0 901510 PA 66, 50 % glass fibers, injection molding, heat-aging stabilized&&

Product Description
SupplierLANXESS
GenericPA66
Material StatusCommercial: Active
FeaturesGood heat aging resistance,Heat Stabilized,HB
AvailabilitysAfrica & Middle East ,North America,Latin America,Asia Pacific,Europe
Process MethodsInjection Molding

Technical Data
PHYSICALNominal valueUnitTest method
Density1.57g/cm³ISO 1183
Apparent density0.70g/cm³ISO 60
Shrinkage rate 
TD:300℃,3.0 mm0.90%ISO 2577
TD:120℃,3.0 mm,2 hrs0.040%ISO 294-4
MD:300℃,3.0 mm0.23%ISO 2577
MD:120℃,3.0 mm,2 hrs0.020%ISO 2577
Water absorption rate
Saturation, 23 ℃4.0%ISO 62
Equilibrium, 23 ℃, 50% RH1.4%ISO 62

filmNominal valueUnitTest method
Membrane puncture strength ISO 6603-2
3.60JISO 6603-2
2.80JISO 6603-2
Membrane puncture force ISO 6603-2
1160NISO 6603-2
1050NISO 6603-2

IMPACTNominal valueUnitTest method
Charpy Notched Impact Strength ISO 179/1eA
-30℃12kJ/m²ISO 179/1eA
23℃15kJ/m²ISO 179/1eA
Charpy Unnotch Impact strength ISO 179/1eU
-30℃100kJ/m²ISO 179/1eU
23℃95kJ/m²ISO 179/1eU
Impact strength of cantilever beam notch ISO 180/1A
-30℃12kJ/m²ISO 180-1A
23℃15kJ/m²ISO 180-1A
Notched impact strength of cantilever beam ISO 180/1U
-30℃85kJ/m²ISO 180/1U
23℃85kJ/m²ISO 180/1U

THERMALNominal valueUnitTest method
Hot deformation temperature
1.8 MPa, unannealed250ISO 75-2/A
0.45 MPa, unannealed250ISO 75-2/B
Vicat Softening Temp 
B50> 230ISO 306
B120> 230ISO 306/B120
Ball pressure test
258℃Pass IEC 60695-10-2
Melting temperature261ISO 11357-3
Linear coefficient of thermal expansion
TD:23~55℃8.0E-51/℃ISO 11359-2
MD:23~55℃2.0E-51/℃ISO 11359-2

Electrical performanceNominal valueUnitTest method
Surface resistivity1.0E+13ohmsIEC 60093
Volume resistivity
23℃1.0E+15ohms·cmIEC 60093
Dielectric strength
23 ℃,1 mm40kV/mmIEC 60243-1
Relative permittivity IEC 60250
23℃,100 Hz4.50 IEC 60250
23℃,1 MHz4.00 IEC 60250
Dissipation factor IEC 60250
23℃,100 Hz9.0E-3 IEC 60250
23℃,1 MHz0.015 IEC 60250
Compared to the leakage tracing index
Solution A550VIEC 60112

FLAME CHARACTERISTICSNominal valueUnitTest method
> 1.00 mmpassed ISO 3795
Flame retardant level UL 94
1.60 mmHB UL 94
3.20 mmHB UL 94
Glowing wire flammability index
2.0 mm600IEC 60695-2-12
Extreme oxygen index27%ISO 4589-2

Supplementary informationNominal valueUnitTest method
ISO ShortnamePA 66, GHR, 14-160, GF50 ISO 1874

MECHANICALNominal valueUnitTest method
Tensile modulus
23℃16000MPaISO 527-1-2
tensile strength
Fracture, 23 ℃230MPaISO 527-2/5
Tensile strain
Fracture, 23 ℃2.6%ISO 527-2/5
Bending modulus
23℃14000MPaISO 178-A
bending strength 
3.50% strainMPaISO 178-A
23℃360MPaISO 178
Bending strain3.0%
Ball hardness246MPaISO 2039-1

Process Conditions
injectionNominal valueUnitTest method
Drying Temperature – Dry Air Dryer80°C
Drying Time – Dry Air Dryer2.0 to 6.0hr
Processing (melt) temperature280 to 300°C
Mold temperature80 to 120°C
Residual Moisture Content0.030 to 0.12%

Notes
【 Disclaimer 】
Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials.