| About |
|---|
| Product Description | |
|---|---|
| Supplier | Mitsui |
| Generic | PA 6T |
| Material Status | Commercial: Active |
| Features | Good Dimensional Stability,Solvent resistance |
| Technical Data | |||
|---|---|---|---|
| PHYSICAL | Nominal value | Unit | Test method |
| Density | 1.63 | ASTM D792 | |
| Shrinkage rate | |||
| MD | 0.3 | % | ASTM D955 |
| TD | 0.7 | % | ASTM D955 |
| Water absorption rate | |||
| 23℃ | 0.3 | % | ASTM D570 |
| 100℃ | 2.7 | % | ASTM D570 |
| MECHANICAL | Nominal value | Unit | Test method |
|---|---|---|---|
| tensile strength | 180 | MPa | ASTM D638 |
| Tensile strain | 3 | % | ASTM D638 |
| bending strength | 300 | MPa | ASTM D790 |
| Bending modulus | 11900 | MPa | ASTM D790 |
| IMPACT | Nominal value | Unit | Test method |
|---|---|---|---|
| Izod notched impact strength | 75 | J/m | ASTM D256 |
| THERMAL | Nominal value | Unit | Test method |
|---|---|---|---|
| melting point | 320 | ℃ | |
| Glass transition temperature | 95 | ℃ | |
| Hot deformation temperature | |||
| 1.82 MPa | 303 | ℃ | ASTM D648 |
| Linear coefficient of thermal expansion | |||
| MD | 2.1E-5 | ℃ | ASTM D696 |
| TD | 7.9E-5 | ℃ | ASTM D696 |
| Electrical performance | Nominal value | Unit | Test method |
|---|---|---|---|
| Volumetric resistance | 1.0E+16 | ohms.m | ASTM D257 |
| Dielectric constant | |||
| 1MHz | 3.6 | ASTM D150 | |
| Dielectric loss | |||
| 1MHz | 0.012 | ASTM D150 | |
| Insulation failure voltage | 24 | kV/mm | ASTM D149 |
| FLAME CHARACTERISTICS | Nominal value | Unit | Test method |
|---|---|---|---|
| Flame retardant level | V-0 | UL 94 |
| Notes |
|---|
| 【 Disclaimer 】 Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials. |