About |
---|
Product Description | |
---|---|
Material Status | Commercial: Negative |
Technical Data | |||
---|---|---|---|
PHYSICAL | Nominal value | Unit | Test method |
Density | 1.81 | g/cm³ | ISO 1183/1A |
Water absorption rate | 0.02 | % | ISO 62 |
Mold shrinkage rate | |||
MD | 0.3 | % | Internal Method |
TD | 0.65 | % | Internal Method |
MECHANICAL | Nominal value | Unit | Test method |
---|---|---|---|
tensile strength | 165 | MPa | ISO 527-1,-2 |
elongation at break | 1.1 | % | ISO 527-1,-2 |
bending strength | 260 | MPa | ISO 178 |
Bending modulus | 18000 | MPa | ISO 178 |
Rockwell hardness | 121 | R Scale | ISO 2039/2 |
IMPACT | Nominal value | Unit | Test method |
---|---|---|---|
Charpy Notched Impact Strength | 8 | kJ/m² | ISO 179/1eU |
Charpy Unnotch Impact strength | 30 | kJ/m² | ISO 179/1eU |
THERMAL | Nominal value | Unit | Test method |
---|---|---|---|
Melting temperature | 280 | ℃ | ISO 11357 |
Linear coefficient of thermal expansion | 14 | μm/m.°C | ISO 11359-1,-2 |
Hot deformation temperature | |||
1.82Mpa | >260 | ℃ | ISO 75-1, -2/A |
FLAME CHARACTERISTICS | Nominal value | Unit | Test method |
---|---|---|---|
Flame retardant level | |||
T=0.8mm | V-0 | UL 94 |
Electrical performance | Nominal value | Unit | Test method |
---|---|---|---|
Dielectric strength | 23 | kV/mm | IEC 60243-1 |
Dielectric constant | 5 | IEC 60250 | |
Dielectric factor | 0.002 | IEC 60250 | |
Compared to the leakage tracing index | 150 | V | IEC 60112 |
Volume resistivity | 1E+16 | ohm·cm | IEC 60093 |
Process Conditions | |||
---|---|---|---|
Injection | Nominal value | Unit | Test method |
drying temperature | 130 | ℃ | |
Drying time | 4 | hr | |
Cylinder temperature | 280 – 330 | ℃ | |
Mold temperature | 130 – 150 | ℃ |
Notes |
---|
【 Disclaimer 】 Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials. |