About |
---|
TECHNYL® A 205F Natural is an unreinforced polyamide 66 for injection moulding. This grade offers two main advantages: excellent filling qualities and UL 94 V2 under 0.4 mm. It is particularly suitable for the moulding of long parts with thin wall sections&& |
Product Description | |
---|---|
Supplier | BASF |
Generic | PA66 |
Material Status | Commercial: Active |
Features | Quick molding cycle,V-2,High liquidity |
Availabilitys | Europe,Latin America,North America,Asia Pacific,Africa & Middle East |
Process Methods | Injection Molding |
Technical Data | |||
---|---|---|---|
PHYSICAL | Nominal value | Unit | Test method |
Mold Shrinkage | |||
Parallel | 1.7 | % | ISO 294-4 |
Normal | 1.7 | % | ISO 294-4 |
Water Absorption | |||
24 h,23℃ | 1.3 | % | ISO 62 |
Moisture Absorption | |||
Equilibrium, 23 ℃. 50% r. h | 3.0 | % | ISO 62 |
Density | 1140 | kg/m³ | ISO 1183 |
MECHANICAL | Nominal value | Unit | Test method |
---|---|---|---|
Tensile Modulus | |||
Dry | 3200 | MPa | ISO 527 |
Wet Cond | 1400 | MPa | ISO 527 |
Tensile Strength | |||
50 mm/min, dry | 85 | MPa | ISO 527-2 |
50 mm/min, moist cond | 50 | MPa | ISO 527-2 |
Yield yld, 2 in/min, dry dry | 85 | MPa | ASTM D638 |
Broken BRK, dry dry | 60 | MPa | ISO 527-2 |
Broken BRK, wet Cond | 40 | MPa | ISO 527-2 |
Tensile Strain | |||
50 mm/min, dry | 4 | % | ISO 527 |
50 mm/min, moist cond | 10 | % | ISO 527 |
Broken BRK, dry dry | 50 | % | ISO 527 |
Broken BRK, wet Cond | 250 | % | ISO 527 |
Elongation at Break | 25 | % | ASTM D638 |
Flexural Modulus | |||
Dry | 3000 | MPa | ISO 178 |
Wet Cond | 1300 | MPa | ISO 178 |
Dry | 3350 | MPa | ASTM D790 |
Flexural Strength | |||
Dry | 120 | MPa | ISO 178 |
Wet Cond | 50 | MPa | ISO 178 |
Dry | 125 | MPa | ISO 178 |
IMPACT | Nominal value | Unit | Test method |
---|---|---|---|
Charpy Notched Impact Strength | |||
Dry | 5 | kJ/m² | ISO 179/1eA |
Wet Cond | 10 | kJ/m² | ISO 179/1eA |
Izod Notched Impact strength | |||
Dry | 5 | KJ/m² | ISO 180/1A |
Wet Cond | 8 | KJ/m² | ISO 180/1A |
Dry | 80 | J/m | ASTM D256 |
THERMAL | Nominal value | Unit | Test method |
---|---|---|---|
Hot deformation temperature HDT | |||
0.45 MPa | 205 | ℃ | ISO 75-1/-2 |
1.80 MPa | 65 | ℃ | ISO 75-1/-2 |
1.8 MPa | 80 | ℃ | ASTM D648 |
0.45 MPa | 80 | ℃ | ASTM D648 |
Melting temperature | 263 | ℃ | ISO 11357-3 |
ELECTRICAL | Nominal value | Unit | Test method |
---|---|---|---|
Surface Resistivity | |||
Dry | 5E15 | ohm | IEC 62631-3-2 |
Wet Cond | 1E14 | ohm | IEC 62631-3-2 |
Volume Resistance | |||
Dry | 1E13 | ohm·m | IEC 62631-3-1 |
Wet Cond | 1E13 | ohm·m | IEC 62631-3-1 |
Electric strength | |||
d=0.8 mm | 35 | kV/mm | IEC 60243-1 |
d=2.0 mm | 22 | kV/mm | IEC 60243-1 |
Dielectric Constant | |||
1 MHz | 3.5 | IEC 62631-2-1 | |
Dissipation Factor | |||
1 MHz | 0.033 | E-4 | IEC 62631-2-1 |
Compared Tracking Index | |||
Test solution A, dry dry | 600 | IEC 60112 | |
Test solution A, moisten cond | 600 | IEC 60112 | |
Test solution B, dry dry | 550 | IEC 60112 |
FLAME CHARACTERISTICS | Nominal value | Unit | Test method |
---|---|---|---|
Flame Class Rating | |||
1.6 mm | V-2 | calss | IEC 60695-11-10 |
0.4 mm | V-2 | calss | IEC 60695-11-10 |
0.8 mm | V-2 | calss | UL-94, IEC 60695 |
3.2 mm | V-2 | calss | UL-94, IEC 60695 |
Glow Wire Flammability Index (GWFI) | |||
1.6 mm | 800 | ℃ | IEC 60695-2-12 |
Oxygen Index | 28 | % | ISO 4589-2 |
Process Conditions | |||
---|---|---|---|
Injection Molding | Nominal value | Unit | Test method |
Drying Temperature | 80 | ℃ | |
Drying Time | 0.2 | hr | |
Front Temperature Zone 3 | 265-275 | ℃ | |
Middle Temperature Zone 2 | 270-280 | ℃ | |
Rear Temperature Zone 1 | 280-285 | ℃ | |
Mold Temperature | 60-80 | ℃ | ISO 294 |
Notes |
---|
1. Typical properties: these are not to be construed as specifications. |
【 Disclaimer 】 Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials. |