About |
---|
BDT246-2CP is a medium to high viscosity curative incorporated fluoroelastomer terpolymer. This grade is well suited for application where good processing properties and superior fluid resistance than standard terpolymers are required. BDT246-2CP can be compounded to meet the major fluoroelastomer specifications. BDT246-2CP can be used for compression molding of O-rings and gaskets. It can be mixed using typical fluoroelastomer compounding ingredients. Mixing can be accomplished with two-roll mills or internal mixers. Finished goods can be produced by a variety of rubber processing methods.&& |
Product Description | |
---|---|
Supplier | Fluoro |
Generic | 氟橡胶 |
Material Status | Commercial: Active |
Features | Excellent Processability,Terpolymer |
Availabilitys | Asia Pacific |
Technical Data | |||
---|---|---|---|
PHYSICAL | Nominal value | Unit | Test method |
Density | 1.86 | g/cm³ | |
Mooney viscosity | |||
ML 1+10,121℃ | 46 | MU | |
Fluorine content | 69 | % | |
solubility | LMW Ketones and esters |
MECHANICAL | Nominal value | Unit | Test method |
---|---|---|---|
Shore hardness | |||
Shaw’s A | 78 | ASTM D2240 |
elastic body | Nominal value | Unit | Test method |
---|---|---|---|
tensile strength | |||
yield | 13.8 | MPa | ASTM D412 |
Tensile strain | |||
fracture | 230 | % | ASTM D412 |
Compression deformation | |||
200℃,70 hr | 26 | % | ASTM D395B |
MH(177℃) | 2.30 | N·m | |
ML(177℃) | 0.240 | N·m | |
t’90(177℃) | 2.7 | min | |
ts2(177℃) | 1.3 | min |
Aging performance | Nominal value | Unit | Test method |
---|---|---|---|
The rate of change in tensile strength | |||
23 ℃, 168 hr, C-grade standard fuel | -30 | % | ASTM D471 |
Change rate of ultimate elongation | |||
23 ℃, 168 hr, C-grade standard fuel | -4.0 | % | ASTM D471 |
The rate of change in Shore hardness | |||
23 ℃, 168 hr, in reference fuel C | -15 | ASTM D471 | |
Volume change | |||
23 ℃, 168 hr, C-grade standard fuel | 20 | % | ASTM D471 |
Notes |
---|
1. Typical properties: these are not to be construed as specifications. |
2. Press Time: 10 min, Press Temperature: 170°C, Post Cure Time: 24 hr, Post Cure Temperature: 230°C |
3. MDR2000 Rheometer, 100cpm, 0.5° Arc, 6 minutes |
【 Disclaimer 】 Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials. |