XENOY™ X2500UV resin

About
XENOY X2500UV is a medium viscosity, unfilled, UV stabilized, elastomer modified PC/PET blend with excellent heat and impact performance. ISO1043-label: PC+PET-I.&&

Product Description
SupplierSABIC
GenericPC+PET
Material StatusCommercial: Active
FeaturesWeather resistance is good,High impact resistance,High Heat Resistance,HB
AvailabilitysEurope
Process MethodsInjection Molding

Technical Data
PHYSICALNominal valueUnitTest method
Density1.21g/cm³ASTM D792 , ISO 1183
Melt Flow Rate
265℃,2.16kg9.0g/10minASTM D1238
Melt Volume Rate
265℃,1.2 kg4.00cm³/10minISO 1133
Shrinkage rate Internal Method
MD0.50 to 0.80%Internal Method
MD:3.2 mm0.50 to 0.80%Internal Method
TD0.50 to 0.80%Internal Method
Water absorption rate ISO 62
Saturation, 23 ℃0.70%ISO 62
Equilibrium, 23 ℃, 50% RH0.20%ISO 62

IMPACTNominal valueUnitTest method
Charpy Notched Impact Strength ISO 179/1eA
-30℃30kJ/m²ISO 179/1eA
23℃50kJ/m²ISO 179/1eA
Charpy Unnotch Impact strength
-30℃无断裂 ISO 179/1eU
Impact strength of cantilever beam notch 
-30℃200J/mASTM D256
0℃450J/mASTM D256
23℃600J/mASTM D256
-40℃15kJ/m²ISO 180-1A
-30℃25kJ/m²ISO 180-1A
23℃40kJ/m²ISO 180-1A
Notched impact strength of cantilever beam
-30℃无断裂 ISO 180/1U
Dart impact equipped with measuring instruments
23℃,Total Energy60.0JASTM D3763

THERMALNominal valueUnitTest method
Hot deformation temperature 
0.45 MPa, unannealed, 64 mm span126ISO 75-2/Bf
1.8 MPa, unannealed, 3.2 mm108ASTM D648
1.8 MPa, unannealed, 64 mm span108ISO 75-2/Af
Vicat Softening Temp 
B50135ASTM D1525 12 , ISO 306/B50 12
A50145ISO 306/A50
B120136ISO 306/B120
Ball pressure test
125℃通过 IEC 60695-10-2
Linear coefficient of thermal expansion 
MD:-40~40℃8.0E-51/℃ASTM E831
MD:23~80℃8.2E-51/℃ISO 11359-2
TD:-40~40℃8.5E-51/℃ASTM E831
TD:23~80℃8.7E-51/℃ISO 11359-2
Thermal conductivity coefficient0.18W/m/KISO 8302

Electrical performanceNominal valueUnitTest method
Surface resistivity> 1.0E+15ohmsIEC 60093
Volume resistivity> 1.0E+14ohms·cmIEC 60093
Dielectric strength
3.2 mm in oil17kV/mmIEC 60243-1
Relative permittivity IEC 60250
50 Hz3.30 IEC 60250
60 Hz3.30 IEC 60250
1 MHz3.10 IEC 60250
Dissipation factor IEC 60250
50 Hz2.0E-3 IEC 60250
60 Hz2.0E-3 IEC 60250
1 MHz0.020 IEC 60250

FLAME CHARACTERISTICSNominal valueUnitTest method
Flame retardant level
1.50 mmHB UL 94
Glowing wire flammability index
2.7 mm750IEC 60695-2-12

MECHANICALNominal valueUnitTest method
Ball hardness
H358/3095.0MPaISO 2039-1
Tensile modulus 
2200MPaASTM D638
2200MPaISO 527-1-2
tensile strength 
yield53.0MPaASTM D638
yield56.0MPaASTM D638
yield57.0MPaISO 527-2/50
fracture55.0MPaASTM D638
fracture56.0MPaISO 527-2/50
Tensile strain 
yield5.0%ASTM D638 , ISO 527-2/50
yield5.0%ASTM D638
fracture100%ASTM D638
fracture80%ASTM D638
fracture70%ISO 527-2/50
Bending modulus 
2100MPaASTM D790
50 mm span2150MPaASTM D790
2150MPaISO 178
bending strength 
79.0MPaASTM D790
80.0MPaISO 178
Yield, 50 mm span79.0MPaASTM D790
Taber abraser
1000 cycles, 1000 g, CS-17 wheels20.0mgInternal Method

Process Conditions
injectionNominal valueUnitTest method
Drying temperature110 to 120°C
Drying time4.0 to 6.0hr
Recommended maximum moisture content0.020%
Hopper temperature60 to 80°C
Barrel rear temperature240 to 270°C
Barrel middle temperature250 to 275°C
Barrel front temperature260 to 280°C
Nozzle temperature260 to 275°C
Processing (melt) temperature265 to 275°C
Mold temperature60 to 100°C

Notes
1. Typical properties: these are not to be construed as specifications.
2. Tensile Bar
3. 2.0 in/min
4. Type I, 2.0 in/min
5. 0.051 in/min
6. 0.079 in/min
7. Yield
8. 80*10*4 sp=62mm
9. 80*10*4
10. 80*10*4 mm
11. Rate B (120°C/h), Loading 2 (50 N)
【 Disclaimer 】
Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials.