ACLAR® Rx20e

About
Aclar® Rx20e is a 0.80 mil (20 micron) CTFE homopolymer, high performance barrier film for the pharmaceutical and medical markets. It thermoforms well on conventional blister packaging equipment and offers all of the benefits of Aclar® in a mid-range barrier material.&&

Product Description
SupplierHoneywell
GenericPCTFE
Material StatusCommercial: Active
FeaturesBlock resin,Homopolymer
AvailabilitysNorth America,Asia Pacific,Europe
Process MethodsThermo forming

Technical Data
PHYSICALNominal valueUnitTest method
Density2.11g/cm³ASTM D1505

filmNominal valueUnitTest method
Secant modulus ASTM D882
MD:20 µm1400MPaASTM D882
TD:20 µm1340MPaASTM D882
tensile strength ASTM D882
MD, yield, 20 µ m89.6MPaASTM D882
TD, yield, 20 µ m47.9MPaASTM D882
Tensile strain ASTM D882
MD, yield, 20 µ m120%ASTM D882
TD, yield, 20 µ m250%ASTM D882
Water vapor transmittance ASTM F1249
20 µm,25℃,60% RH0.039g·mm/m²/atm/24 hrASTM F1249
20 µm,30℃,60% RH0.062g·mm/m²/atm/24 hrASTM F1249
20 µm,40℃,75% RH0.26g·mm/m²/atm/24 hrASTM F1249
20 µm,38℃,100% RH0.29g·mm/m²/atm/24 hrASTM F1249

THERMALNominal valueUnitTest method
Crystallization peak temperature
DSC211ASTM D3418

optical performanceNominal valueUnitTest method
Haze
20.3 µm< 1.0%ASTM D1003

Notes
1. Typical properties: these are not to be construed as specifications.
【 Disclaimer 】
Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials.