AEI TP521

About
Thermoplastic, low smoke, halogen free, flame retardant compound for cable insulation and sheathing. This is a flame retardant, low smoke, thermoplastic compound which has been specially developed to meet the requirements of limited toxic and corrosive fume emission, having good moisture resistance and hot pressure performance. TP521 has been specially developed to comply with the requirements of BS7655 Section 6 for types LTS1,2,3 and 4; EN 50290-2-27 for type HM2 and HD 604 for type HM4. Cables made with TP521 have passed the 3m³ smoke chamber test. TP521 is available in the following versions: TP521N (natural colour) TP521B (coloured black) TP521NU (with a non-staining UV stabiliser added) TP521BU (carbon black added to give UV stability)&&

Product Description
GenericPE
Material StatusCommercial: Active
FeaturesWeather resistance is good,Low smoke,Halogen free,Flame Characteristics,Moisture resistance
AvailabilitysAfrica & Middle East ,North America,Latin America,Asia Pacific,Europe
Process MethodsExtrusion

Technical Data
PHYSICALNominal valueUnitTest method
Density1.50g/cm³BS 2782 620A
Melt Flow Rate
150℃,21.6kg6.0g/10minInternal Method

Aging performanceNominal valueUnitTest method
The rate of change in tensile strength 
23 ℃, 4 hr, in ASTM # 2 oil9.0%
70 ℃, 4 hours, in ASTM # 2 oil14%
100 ℃, 4 hours, in ASTM # 2 oil28%
100℃,168 hr-10%IEC 60811-1-2
Changes in tensile stress during fracture 
23 ℃, 4 hr, in ASTM # 2 oil2.0%
70 ℃, 4 hours, in ASTM # 2 oil24%
100 ℃, 4 hours, in ASTM # 2 oil48%
100℃,168 hr13%IEC 60811-1-2

THERMALNominal valueUnitTest method
deformation
100℃30%IEC 60811-3-1
Cold shock
-30℃pass IEC 60811-1-4
Low temperature bending
-50℃pass IEC 60811-1-4
Heat resistant stress cracking
80℃pass Internal Method
Temperature index270ISO 4589-3

Electrical performanceNominal valueUnitTest method
Insulation resistance constant – Ki IEC 60502
20℃7.7E+9ohms·cmIEC 60502
90℃5.7E+7ohms·cmIEC 60502

FLAME CHARACTERISTICSNominal valueUnitTest method
Extreme oxygen index30%ISO 4589-2
smoke
3m cube testpass EN 61034

Supplementary informationNominal valueUnitTest method
Halogen Acid Gas Evolution< 0.50%IEC 60754-1
tear strength7N/mmBS 6469

MECHANICALNominal valueUnitTest method
Shore hardness
Shaw’s A90 
tensile strength13.0MPaIEC 60811-1-1
Tensile strain 
fracture160%IEC 60811-1-1
Fracture, -30 ℃60%IEC 60811-1-4

Process Conditions
ExtrusionNominal valueUnitTest method
Barrel 1 zone temperature120°C
Barrel 2 zone temperature130°C
Barrel 3 zone temperature140°C
Barrel 4 zone temperature150°C
Melt temperature< 170°C
Head temperature160°C
Nozzle temperature160°C

Notes
【 Disclaimer 】
Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials.