About |
---|
APTIV® 1000 series films are the unfilled semi-crystalline films made from VICTREX® PEEK™ polymer. The film provides a material solution for engineers in ultra-high performance applications. APTIV films are a comprehensive range of versatile, high-performance films, the use of which can facilitate reduced systems costs, improved performance and enhanced design freedom. APTIV 1000 has a unique combination of properties providing high temperature performance, light weight, mechanical strength, durability, excellent radiation, hydrolysis and chemical resistance, electrical insulation, wear and abrasion resistance, excellent barrier properties with high purity, good flammability without the use of flame retardants, low toxicity of combustion products, and low moisture absorption in a film format. Inherently halogen free and ease of processing makes APTIV films a technology enabler for our customers and end users.&& |
Product Description | |
---|---|
Supplier | Victrex |
Material Status | Commercial: Active |
Features | Block resin,High purity,Good Printability,Good Rigidity,Halogen free,Hydrolysis stability,Hypocrystalline,Electroplating,Durability,Good wear resistance,Low smoke,Welding,Insulation,Renewable resources,Flame Characteristics,Solvent resistance,High Heat Resistance,Excellent Processability,Good heat sealing,Good flexibility,Low toxicity,Gamma radiation,Low moisture absorption |
Availabilitys | Europe,Latin America,Asia Pacific,Africa & Middle East ,North America |
Process Methods | Thermo forming |
Technical Data | |||
---|---|---|---|
PHYSICAL | Nominal value | Unit | Test method |
Density | 1.30 | g/cm³ | ISO 1183 |
Water Absorption | |||
Equilibrium balanced, 23 ℃, 50% RH, 0.05 mm | 0.040 | % | ISO 62 |
Molding shrinkage | |||
200℃,50.0 µm | < 2.0 | % |
MECHANICAL | Nominal value | Unit | Test method |
---|---|---|---|
Film thickness | 8 to 750 µm | ||
Tensile Modulus | ISO 527-3 | ||
23℃,25 µm | 3000 | MPa | ISO 527-3 |
23℃,50 µm | 2800 | MPa | ISO 527-3 |
23℃,130 µm | 2400 | MPa | ISO 527-3 |
23℃,250 µm | 2200 | MPa | ISO 527-3 |
Tensile Strength | ISO 527-3 | ||
Broken BRK, 23 ℃, 25 µ m | 130 | MPa | ISO 527-3 |
Broken BRK, 23 ℃, 50 µ m | 120 | MPa | ISO 527-3 |
Broken BRK, 23 ℃, 130 µ m | 110 | MPa | ISO 527-3 |
Broken BRK, 23 ℃, 250 µ m | 100 | MPa | ISO 527-3 |
Tensile Strain | ISO 527-3 | ||
Broken BRK, 23 ℃, 25 µ m | > 150 | % | ISO 527-3 |
Broken BRK, 23 ℃, 50 µ m | > 150 | % | ISO 527-3 |
Broken BRK, 23 ℃, 130 µ m | > 150 | % | ISO 527-3 |
Broken BRK, 23 ℃, 250 µ m | > 150 | % | ISO 527-3 |
Pant shape tear resistance | |||
50 µm | 6.70 | N/mm | ISO 6383-1 |
THERMAL | Nominal value | Unit | Test method |
---|---|---|---|
Coeff. of linear thermal expansion | |||
MD:0.05 mm | 4.7E-5 | 1/℃ | ASTM D696 |
ELECTRICAL | Nominal value | Unit | Test method |
---|---|---|---|
Volume Resistance | |||
23 ℃,0.05 mm | 4.0E+16 | ohms·cm | ASTM D257 |
Dielectric Strength | ASTM D149 | ||
23 ℃,0.025 mm | 270 | kV/mm | ASTM D149 |
23 ℃,0.05 mm | 190 | kV/mm | ASTM D149 |
23 ℃,0.125 mm | 120 | kV/mm | ASTM D149 |
23 ℃,0.25 mm | 70 | kV/mm | ASTM D149 |
Dielectric Constant | |||
23 ℃,0.05 mm,10 MHz | 3.50 | ASTM D150 | |
Dissipation Factor | |||
23℃,0.05 mm,10 MHz | 2.0E-3 | ASTM D150 | |
Breakdown voltage | ASTM D149 | ||
23℃,25.0 µm | 6750 | V | ASTM D149 |
23℃,50.0 µm | 9500 | V | ASTM D149 |
23℃,125.0 µm | 15000 | V | ASTM D149 |
23℃,250.0 µm | 17500 | V | ASTM D149 |
Supplementary Information | Nominal value | Unit | Test method |
---|---|---|---|
Puncture Resistance | |||
23℃,50.0 µm | 26.0 | kJ/m² | Internal Method |
Notes |
---|
1. Typical properties: these are not to be construed as specifications. |
2. 24 hrs |
3. TM-VX-84 |
4. 23°C |
5. below Tg |
6. 100 V |
7. 0.25 inch electrode |
【 Disclaimer 】 Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials. |