About |
---|
ATTANE™ SL 4100G Ultra Low Density Polyethylene Resin is designed for the production of blown film requiring a combination of excellent optical properties, outstanding tear and impact strength, and very good sealability. The product also offers very good flex crack resistance. Complies with: EU, No 10/2011 U.S. FDA 21 CFR 176.170(c) U.S. FDA FCN 424 Consult the regulations for complete details.&& |
Product Description | |
---|---|
Supplier | DOW |
Generic | VLDPE |
Material Status | Commercial: Negative |
Availabilitys | Europe |
Technical Data | |||
---|---|---|---|
PHYSICAL | Nominal value | Unit | Test method |
Density | 0.912 | g/cm³ | ASTM D792 |
Melt Flow Rate | |||
190℃,2.16kg | 1.0 | g/10min | ISO 1133 |
film | Nominal value | Unit | Test method |
---|---|---|---|
film thickness | |||
test | 40 | µm | |
Tensile modulus | ISO 527-3 | ||
2% secant, MD, 40 µ m | 120 | MPa | ISO 527-3 |
2% secant, TD, 40 µ m | 135 | MPa | ISO 527-3 |
tensile strength | ISO 527-3 | ||
MD, yield, 40 µ m | 6.50 | MPa | ISO 527-3 |
TD, yield, 40 µ m | 6.20 | MPa | ISO 527-3 |
MD, fracture, 40 µ m | 31.0 | MPa | ISO 527-3 |
TD, fracture, 40 µ m | 30.0 | MPa | ISO 527-3 |
Tensile strain | ISO 527-3 | ||
MD, fracture, 40 µ m | 640 | % | ISO 527-3 |
TD, fracture, 40 µ m | 760 | % | ISO 527-3 |
Drop hammer impact | |||
40 µm | 850 | g | ISO 7765-1/B |
Elmandorf tear strength | ASTM D1922 | ||
MD:40 µm | 690 | g | ASTM D1922 |
TD:40 µm | 850 | g | ASTM D1922 |
THERMAL | Nominal value | Unit | Test method |
---|---|---|---|
Vicat Softening Temp | 92.0 | ℃ | ASTM D1525 |
Melting temperature | 122 | ℃ | DSC |
optical performance | Nominal value | Unit | Test method |
---|---|---|---|
gloss | |||
20°,40 µm | 75 | ASTM D2457 | |
Haze | |||
40 µm | 8.0 | % | ISO 14782 |
Process Conditions | |||
---|---|---|---|
Extrusion | Nominal value | Unit | Test method |
Melt temperature | 190 to 240 | °C |
Notes |
---|
1. Conditions of Use A through H |
2. Typical properties: these are not to be construed as specifications. |
3. Compression moulded samples |
【 Disclaimer 】 Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials. |