About |
---|
MP-6510 is a maximum-properties, electrical grade injection molding PVC compound for interior applications. This compound possesses excellent strength and toughness and has good processing stability and surface appearance. MP-6510 carries a UL 94 V-0/5VA flammability rating, as well as a UL RTI rating.&& |
Product Description | |
---|---|
Supplier | Axiall Corporation |
Generic | PVC,刚硬 |
Material Status | Commercial: Active |
Features | Good Rigidity,Excellent Processability,Good flexibility,Good surface appearance |
Availabilitys | North America |
Process Methods | Injection Molding |
Technical Data | |||
---|---|---|---|
PHYSICAL | Nominal value | Unit | Test method |
Density | 1.33 to 1.37 | g/cm³ | ASTM D792 |
Shrinkage rate | |||
MD | 0.30 to 0.40 | % | ASTM D955 |
PVC unit classification | 16344 | ASTM D1784 | |
Flow Ratio(199 to 204℃) | 180 | Internal Method |
MECHANICAL | Nominal value | Unit | Test method |
---|---|---|---|
Shore hardness | |||
Shore D, 10 seconds | 78 | ASTM D2240 | |
Tensile modulus | 2480 | MPa | ASTM D638 |
tensile strength | |||
yield | 41.4 | MPa | ASTM D638 |
Bending modulus | 2620 | MPa | ASTM D790 |
bending strength | 75.8 | MPa | ASTM D790 |
IMPACT | Nominal value | Unit | Test method |
---|---|---|---|
Impact strength of cantilever beam notch | ASTM D256 | ||
-20℃,3.2mm | 160 | J/m | ASTM D256 |
23℃,3.2mm | 960 | J/m | ASTM D256 |
Resistance to drop impact | |||
23℃ | 89.0 | J/cm | ASTM D4226 |
THERMAL | Nominal value | Unit | Test method |
---|---|---|---|
Hot deformation temperature | |||
1.8 MPa, unannealed | 70.0 | ℃ | ASTM D648 |
0.45 MPa, unannealed | 75.0 | ℃ | ASTM D648 |
Relative temperature index | |||
Electrical performance | 90.0 | ℃ | UL 746 |
Strength mechanical performance | 90.0 | ℃ | UL 746 |
Impact mechanical performance | 85.0 | ℃ | UL 746 |
FLAME CHARACTERISTICS | Nominal value | Unit | Test method |
---|---|---|---|
Flame retardant level | V-0 5VA | UL 94 | |
Extreme oxygen index | 36 | % | ASTM D2863 |
Supplementary information | Nominal value | Unit | Test method |
---|---|---|---|
Weathering resistance | F1 | UL 746C |
Notes |
---|
1. Typical properties: these are not to be construed as specifications. |
2. Distance/Wall Thickness |
3. Procedure A, C 1/2″ R Tup |
【 Disclaimer 】 Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials. |