About |
---|
Glass fiber reinforced PA6 compound&& |
Product Description | |
---|---|
Supplier | Polyone |
Generic | PA6 |
Material Status | Commercial: Active |
Availabilitys | Africa & Middle East ,Europe |
Process Methods | Injection Molding |
Technical Data | |||
---|---|---|---|
PHYSICAL | Nominal value | Unit | Test method |
Density | 1.26 to 1.30 | g/cm³ | ISO 1183 |
MECHANICAL | Nominal value | Unit | Test method |
---|---|---|---|
Tensile modulus | 7000 | MPa | ISO 527-2 |
tensile strength | |||
fracture | 150 | MPa | ISO 527-2 |
Tensile strain | |||
fracture | 3.5 | % | ISO 527-2 |
IMPACT | Nominal value | Unit | Test method |
---|---|---|---|
Charpy Notched Impact Strength | |||
23℃ | 10 | kJ/m² | ISO 179 |
Charpy Unnotch Impact strength | |||
23℃ | 70 | kJ/m² | ISO 179 |
THERMAL | Nominal value | Unit | Test method |
---|---|---|---|
Hot deformation temperature | |||
0.45 MPa, unannealed | 220 | ℃ | ISO 75-2/B |
1.8 MPa, unannealed | 200 | ℃ | ISO 75-2/A |
Melting temperature | |||
DSC | 215 to 225 | ℃ | ISO 3146 |
Electrical performance | Nominal value | Unit | Test method |
---|---|---|---|
Compared to the leakage tracing index | 500 | V | IEC 60112 |
FLAME CHARACTERISTICS | Nominal value | Unit | Test method |
---|---|---|---|
Flame retardant level | |||
3.20 mm | HB | Internal Method |
Process Conditions | |||
---|---|---|---|
injection | Nominal value | Unit | Test method |
Drying temperature | 80 | °C | |
Drying time | 4.0 | hr | |
Processing (melt) temperature | 260 to 290 | °C | |
Mold temperature | 50 to 90 | °C |
Notes |
---|
1. Typical properties: these are not to be construed as specifications. |
【 Disclaimer 】 Guangzhou Soliao Information Technology Co., Ltd. reserves all rights. The information in this data table was obtained from the manufacturer of the material on soliao.com. Soliao.com makes every effort to ensure the accuracy of this data. However, the search company does not assume any responsibility for the uncertainty and consequences caused to users by these data values and suggestions, and strongly recommends verifying the data values with the material supplier before the final selection of materials. |